Crusader PowerView Instruction Sheet 
INITIAL TWIN ENGINE SET UP 
1. 
After installation start your engines. Both PowerView 
units will be reading the Master engine.  Choose to leave 
one engine running and kill the other.  
2. 
While the one engine is running, press MENU on the 
PowerView keypad.  Scroll down to the bottom of the 
second page until UTILITIES is highlighted.  Press 
Enter. 
 
3. 
Within the UTILITIES menu you will find a list of options.   
4. 
Scroll to the bottom of the second page until “SELECT 
ENGINE ECU” is highlighted.  Press ENTER. 
5. 
This screen will default to listen to the Master engine (0).  
To change this to listen to the Slave engine (1) press the 
right arrow key.  1 will appear on the screen.  Press 
ENTER.   
NOTE:  Make sure to press ENTER after selecting ECU 
1 in order to activate your selection.   
6. 
Press MENU to go back to the main data screens.  You 
should now have data available for the engine.  If you do 
not, then the engine you are working with is the Master 
and should be set to 0 and the other engine is the Slave 
and should be set to 1.  Repeat this process to change 
the other PowerView unit.