Mocomtech CDM-570 Manuale Utente

Pagina di 452
CDM-570/570L Satellite Modem with Optional IP Module 
Revision 4 
Appendix F 
MN/CDM570L.IOM 
F.3.3.3 (ODU,ENABLE,1:1) RED-BOX (Redundancy Controller Box) 
 Redundancy Box:  Online  
 Mode  Switches  Voltages 
 
The user is prompted to select from 1 of 4 items. 
F.3.3.4 (ODU,ENABLE,1:1,RED 
BOX) 
ONLINE 
 Online Unit:  
 CSAT#1  CSAT#2  (
◄ ►,
ENT) 
 
The cursor will be flashing under either CSAT#1 or CSAT#2.  This is the indication of 
the currently Online unit.  If the user desires to change the Online unit the 
◄ ► 
arrow 
keys are used to move the cursor position and then the ENT key must be depressed. 
 
NOTE: If the ODU Redundancy system is in AUTO mode, a ‘forced switch-over’ can 
only occurs if the currently Offline unit is fault-free. 
F.3.3.5 (ODU,ENABLE,1:1,RED 
BOX) 
MODE 
 Operating Mode: 
 Manual  Auto    (
◄ ►,
ENT) 
 
The cursor will be flashing under either Manual or Auto.  This is the indication of the 
current operating mode of the 1:1 ODU system.  If the user desires to change the 
operating mode of the 1:1 system, the 
◄ ► 
arrow keys are used to move the cursor 
position and then the ENT key must be depressed. 
F.3.3.6 (ODU,ENABLE,1:1,RED 
BOX) 
SWITCHES 
 Waveguide Switch Status: 
 Tx=OK Rx=OK (ENT or CLR) 
 
This menu item provides the status of both the Tx and Rx Waveguide transfer Switches.  
If either Switch is reporting an ambiguity from the commanded position the “OK” will 
change to “FT”.  This indicates a switch fault. 
F.3.3.7 (ODU,ENABLE,1:1,RED 
BOX) 
VOLTAGES 
 Redundancy Box Voltages: 
 5V= 5.0  12V=12.0  (ENT) 
 
This menu item provides monitor of the voltages inside the Redundancy Controller Box.  
This is provided to assist in trouble-shooting system problems. 
F–4