Maxon Telecom MM-5100 Manuale Utente

Pagina di 44
 
MM-5100 Windows Setup Manual 090803 NZ 
Page 8 of 44 
 4/09/2003 
5 .   L E D   F U N C T I O N S  
This section describes the labelling and functions of the LED on the MM-5100. 
The RSSI LED will be OFF when RSSI is less than -105dBm, flashing when in-between the -
95dBm and -105dBm, and ON when greater than or equal to -95dBm. 
NOTE: the higher the negative number i.e. the further away from ZERO, the weaker the received signal. 
The smaller the number i.e. the closer to ZERO, the stronger the received signal.  
A flashing RSSI LED indicates potential need for an alternative antenna, relocating the 
antenna to a site more suited to signal acquisition, or elevation of the antenna to improve 
signal acquisition, or a combination of all the above. 
A consistent RSSI reading of -95dBm or better [number closer to ‘0’] is advisable. 
LED Label  Description 
pwr 
Lit continuously when power is applied to modem 
dtr 
To indicate MODEM is live on Host device 
sms 
Blinks if there is unread SMS message 
ri/rx 
Blinks on incoming voice call, lights continuously on incoming data call, 
blinks on data from PC to MODEM 
tx 
Blinks on data from MODEM to PC 
rssi 
Lights continuously in RSSI range > -95dBm (This is the preferred range) 
Blinks in RSSI range -95dBm > -105dBm, (Signal is marginal) 
Turn-off at RSSI < -105dBm (No signal available) 
roam 
ON when inside a preferred roaming carrier network but outside Telstra’s 
network, FLASHES when inside a non-preferred roaming carrier network but 
outside Telstra’s network, OFF when inside Telstra network 
crt 
To indicate connection in Circuit Switched mode 
pkt 
To indicate active connection in Packet Switched mode (OFF when in dormant 
mode) 
1x cell 
To indicate that local cell supports Packet Switched data (OFF indicates cell 
supports only IS95A) 
Note 1: In ALL-LED-OFF state, when you connect ear piece to the MM-5100, the LED’s are enabled for a 
value set by AT command AT$$EXT_LED=<1~255sec>. If LED always ON is required, change the 
AT command parameter to ‘0’. 
Note 2: If the LED’s have been disabled by AT command prior to power cycle, all LED’s will remain in 
OFF state until ear-piece is connected.