4  Troubleshooting 
If you notice unexpected operation of the Maretron RIM100, follow the troubleshooting 
procedures in this section to remedy simple problems. If these steps do not solve your 
problem, please contact Maretron Technical Support (refer to Section 6 for contact 
information). 
 
Symptom 
Troubleshooting Procedure 
No Run Indicator data 
visible on NMEA 2000
®
 
network. 
Ensure that the RIM100 is properly connected to the NMEA 2000
®
 
network. 
 
Ensure that the monitored loads are properly connected to the 
RIM100. 
 
Ensure that each indicator that you wish to monitor is not 
configured as “Disabled”. 
 
Ensure that the RIM100 has the appropriate NMEA 2000
®
 PGNs 
enabled as described in Section 2.5.5
A Run Indicator always 
reads “Off” 
Ensure that there is not an open circuit in the wiring for the load. 
With the load running, measure the voltage between the “+” and “-” 
terminals on the RIM100 to which the load is connected. You 
should measure an appropriate AC or DC voltage, depending upon 
the type of load.