Maretron Run Indicator Module RIM100 Manuale Utente

Pagina di 17
 
RIM100 User's Manual  
 
 
Figure 2 – NMEA 2000
®
 Connector Face Views 
 
2.4.2  Monitored Load Connections 
The RIM100 monitored load connections are made by connecting to the 12-pin terminal strip 
on the top of the unit.  First, remove the four screws at the corners of the unit detaching the 
splash guard from the unit.  On the bottom of the splash guard, you will find a label detailing 
the wire connection to pin number assignments, which are repeated in the table below. 
 
Pin # 
Signal Name 
Connection 
V1+ 
Voltage #1 (+ for DC monitored loads) 
V1- 
Voltage #1 (- for DC monitored loads) 
V2+ 
Voltage #2 (+ for DC monitored loads) 
V2- 
Voltage #2 (- for DC monitored loads) 
V3+ 
Voltage #3 (+ for DC monitored loads) 
V3- 
Voltage #3 (- for DC monitored loads) 
V4+ 
Voltage #4 (+ for DC monitored loads) 
V4- 
Voltage #4 (- for DC monitored loads) 
V5+ 
Voltage #5 (+ for DC monitored loads) 
10 
V5- 
Voltage #5 (- for DC monitored loads) 
11 
V6+ 
Voltage #6 (+ for DC monitored loads) 
12 
V6- 
Voltage #6 (- for DC monitored loads) 
 
 
The RIM100 will detect the presence or absence of either AC or DC voltages. Before 
attempting to connect the RIM100 to the AC source, determine the type of system you will be 
monitoring. The RIM100 supports the connection and monitoring of two different system types; 
1) AC loads (Section 2.4.2.1), or 2) DC loads (Section 2.4.2.2).  
 
 
 
 