Magma MDR 24/96 Manuale Utente

Pagina di 44
25
Quick Start Guide
Quick 
Star
Guide
Note:
Note:
Note:
Note:
Note:  Determining
which unit in 
Figure 4
provides master
clock depends on
your  application. For
information on ad-
vanced applications,
see the Technical
Reference manual.
AES/EBU Hookup (PDI•8)
Cables & Hardware
(3) PDI•8 cards for MDR24/96
(3) PDI•8 cards for D8B
(1) Clock I/O card for D8B
(3) DB25 to DB25 AES/EBU snakes
(1) 75
Ω BNC word clock cable
Hookup
1.  Connect the three AES/EBU cables between the corresponding AES/EBU
connectors on the MDR24/96 and D8B.
2.  When AES/EBU is used, the D8B must have a Clock I/O card installed. To
make the D8B the clock master, connect its Word Clock Out to the
MDR24/96 Word Clock In. To make the MDR24/96 the master, connect its
Word Clock Out to the D8B Word Clock In.
MDR24/96 Settings
1.  If the MDR24/96 is the clock master, set the Sample Clock to Internal; if
it is a clock slave, set the Sample Clock to Word Clock and depress the
75
Ω
Ω
Ω
Ω
Ω termination switch on the Sync card.
2.  Set the Sample Rate to 44.1 kHz or 48 kHz according to your preference.
Console Settings
1.  If the D8B is the clock master, set the Sample Clock to either 44.1 k
Internal 
or 48 k Internal; if it is a clock slave, set the Sample Clock to
either 44.1 kHz or 48 kHz. Set the sample rate to match the Sample Rate
selected on the MDR24/96.
OK, so we fibbed a little. You can use PDI•8 cards in the D8B without a Clock I/O
card installed, but doing so requires that you enable sample rate conversion on
both the D8B and the MDR24/96 in lieu of word clock synchronization. Sample
rate conversion results in  a 4-bit loss in sample resolution that may degrade
the quality of the sound slightly. So, the moral of the story is that unless you
just blew your wad on a new guitar and are eating peanut butter sandwiches
until your next paycheck, go buy a Clock I/O card.