Lucent Technologies Definity Enterprise Communication Server 8.2 Manuale Utente

Pagina di 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
654
Feature-Related System Parameters 
17
Auto Hold
Conference Parties without Public Network 
Trunks
Enter a number to specify the maximum number of parties allowed in a 
conference call involving no public network trunks.
Attendant Tone
Night Service Disconnect Timer (seconds)
Enter a number or blank to indicate how long a trunk call can be unanswered 
during night service before being disconnected. The trunk must not have 
Disconnect Supervision for this timer to apply.
Bridging Tone
Short Interdigit Timer (seconds)
Enter a number to limit the time that digit analysis will wait for the next digit 
when it has predicted that all the digits have already been collected.
Valid entries
Usage
y/n
 Enter 
y
 to enable the Automatic Hold feature on a 
system-wide basis.
Valid entries
Usage
3
 to 
6
Valid entries
Usage
y/n
 Enter 
y
 to provide call progress tones to the attendants.
Valid entries
Usage
10
 to 
1024
 
Valid entries
Usage
y/n
 Enter 
y
 to apply a bridging tone when calls are bridged on 
primary extensions.
Valid entries
Usage
3
 to 
9