Screen reference 
704
Hunt Group 
17
Time Warning Threshold
Appears if the Queue field is 
y
 and when the Calling Warning Port and the Time 
Warning Port fields are 
X
. Enter the time in seconds that a call can remain in the 
queue before the System flashes the Queue status lamps (feature buttons assigned 
members phones) and the Auxiliary Queue Time Warning lamp assigned to this 
split/skill. 
(Time Warning) Port
Appears if the Queue field is 
y
. Enter the seven-character port number assigned to 
the Auxiliary Queue Time Warning lamp that flashes when the time entered in 
Time Warning Threshold has been reached by a call in queue. 
NOTE:
This port is assigned to an Analog Line circuit pack or given an "X" 
designation if an extension is used.
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number 
(port) 12.
(Time Warning) Extension
Appears if the Queue field is 
y
. An extension is needed when an X is placed in 
Time Warning Port. This extension can be used by the Terminal Translation 
Initialization (TTI) feature to assign a port to this extension from the port itself. 
Once Time Warning Port is assigned a valid port (either via TTI or the 
change 
hunt-group
 command), then the extension is removed and considered 
unassigned.
Valid entries
Usage
0
 to 
999
An entry of 
0
 provides a warning whenever a call is queued.
Valid entries
Usage
01
 through 
44
First and second characters are the cabinet number
01
 through 
03
01
A
 through 
E
Third character is the carrier number
01
 through 
20
Fourth and fifth characters are the slot number
01
 through 
16
Sixth and seventh characters are the circuit number
Valid entries
Usage
Enter an unassigned extension. This field may not be blank.