Lucent Technologies Definity Enterprise Communication Server 8.2 Manuale Utente

Pagina di 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
770
ISDN trunk group 
17
H0
Enter 
y
 to specify the ISDN information transfer rate for 384-kbps of data, which 
is comprised of six B-channels. When a trunk group is administered to support 
H0, the trunk/hunt algorithm to satisfy a call requiring 384-kbps of bandwidth 
uses a fixed allocation scheme.
H11
Enter 
y
 to specify the ISDN information transfer rate for 1536-kbps of data, which 
is comprised of 24 B-channels. When a trunk group is administered to support 
H11, the trunk/hunt algorithm to satisfy a call requiring 1536-kbps bandwidth 
uses a fixed allocation scheme.
H12
Enter 
y
 to specify the ISDN information transfer rate for 1920-kbps of data, which 
is comprised of 30 B-channels. When a trunk group is administered to support 
H12, the trunk/hunt algorithm to satisfy a call requiring 1920-kbps bandwidth 
uses a fixed allocation scheme.
NxDS0
Enter 
y
 to specify the “N by DS-zero” multi-rate service.
Contiguous
Specifies whether or not to hunt contiguous NXDS0 channels. This field only 
appears if the NxDS0 field is 
y
.
The trunk/hunt algorithm to satisfy an NXDS0 call is as follows:
— Enter 
y
 to specify the “floating” scheme. NXDS0 calls are placed on 
a contiguous group of B-channels large enough to satisfy the 
requested bandwidth without constraint on the starting channel (no 
fixed starting point trunk).
NOTE:
H0 and NXDS0 “floating” scheme cannot both be 
y
.
— Enter 
n
 to specify the “flexible” scheme. NXDS0 calls are placed on 
any set of B-channels on the same facility as long as the requested 
bandwidth is satisfied. There are no constraints such as contiguity of 
B-channels or fixed starting points.