Lucent Technologies Definity Enterprise Communication Server 8.2 Manuale Utente
DEFINITY ECS Release 8.2
Administrator’s Guide
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
1010
Trunk Group
17
Field descriptions for page 3
The figure below shows a common configuration for page 3 of the Trunk Group
screen when the Group Type field is
screen when the Group Type field is
co
. This screen is only an example, and the
fields shown below may change or disappear according to specific field settings.
Screen 212.
Administrable Timers for Trunk Group
!
CAUTION:
Customers: Do not change fields on this page without assistance from
Lucent Technologies or your network service provider.
Lucent Technologies or your network service provider.
Send Incoming/Outgoing Disconnect Timers to
TN465 Ports
TN465 Ports
The field appears only for a co, fx, or wats trunk group.
Valid entries
Usage
y/n
Enter
y
if you want to send the incoming disconnect and
outgoing disconnect timer values to the trunk group ports that
are on a TN465 board.
are on a TN465 board.
add trunk-group next
Page 3 of x
ADMINISTRABLE TIMERS
Send Incoming/Outgoing Disconnect Timers to TN465 Ports? _
Outgoing Dial Guard(msec): _____
Incoming Glare Guard(msec): _____
Outgoing Glare Guard(msec): _____
Outgoing Rotary Dial Interdigit (msec): ____
Ringing Monitor(msec): _____
Ringing Monitor(msec): _____
Incoming Seizure(msec): ____
Outgoing End of Dial(sec): ___
Outgoing Seizure Response(sec): ___
Programmed Dial Pause(msec): _____
Disconnect Signal Error(sec): ___
Flash Length(msec): ____
END TO END SIGNALING
Tone (msec): ____
Pause (msec): 150
OUTPULSING INFORMATION
PPS: 10
Make(msec): 40
Break(msec): 60 PPM? y
Frequency: 50/12k