Low Profile – 1600-000-A Advantage Series Service Manual – Domestic
 
 
 
Cooling Fan(s) 
120 VAC should be at the motor.  If voltage is present, check 
motor for shorts, opens, or grounds.  WITH POWER OFF: 
check for locked rotor. 
Gas Supply 
Check for adequate gas supply and closed manual gas valves.  
Also, check flexible gas line connection. 
Main Fan 
If not operating, refer to "Oven fan will not run". 
Oven will not heat 
 
 
NOTE:  These ovens utilize 2 complete burner/temperature control systems.  Each system will follow the same 
troubleshooting sequence. 
Centrifugal Switch of 
Main Fan Motor 
Check for 120 VAC supplied to the centrifugal switch, if 
voltage is not present, trace the wiring back to the oven power 
relay.  Check for 120 VAC out of the centrifugal switch.  If 
voltage is supplied to the centrifugal switch, and motor is 
running, but there is no voltage out of the centrifugal switch, 
replace the fan motor. 
(NOTE:  See Schematic Diagram of proper wire numbers on 
motors.) 
Fuse, Burner 10A 
Check, replace if necessary. 
Fuse holder 
Check, replace if necessary 
Burner Blower Motor 
Check for 120 VAC supply to the burner blower motor, if 120 
VAC is present and motor does not turn, replace the motor. 
Burner Transformer 
Check for 120 VAC to primary of the 24 VAC burner 
transformer.  If voltage is not present, trace wiring back to the 
fuse.  If voltage is present, check for 24 VAC at the secondary, 
if no secondary voltage is present, replace the transformer. 
Centrifugal Switch of 
Burner Blower Motor 
Check for 24 VAC supply to the centrifugal switch of burner 
blower motor (see Schematic for proper wire numbers).  If no 
voltage is present, trace wiring back to the transformer.  If 
voltage is present, check for 24 VAC at the output of the 
centrifugal switch.  If there is no output, and the burner blower 
motor is running, replace the burner blower motor. 
Ignition Control 
Check for 24 VAC supply to the ignition control at terminals 
marked 24V and 24Vgnd.  If voltage is not present, trace 
wiring back to the centrifugal switch.  Check for 120VAC 
supply to the ignition control at terminals L1 and L2.  If no 
voltage is present, trace wiring back to fuse. If the above 
checks are okay, proceed. The ignition control should switch 
120VAC to the hot surface igniter, across the (2) terminals 
marked HIS. If no voltage is present, replace the ignition 
control. 
Hot Surface Igniter 
(Located inside Burner 
Assy) 
If 120 VAC is present at HSI terminals, visually check to see 
that the hot surface igniter is heating (igniter may be viewed 
through port glass in end of burner tube).  The igniter should 
glow bright red.  Check all connections to be sure they are 
tight.  If the igniter does not heat, replace. 
 
Ignition Control 
After 45 seconds of hot surface igniter pre-heat, the ignition 
control will switch 24 VAC to the gas control valves.  Check for 
24 VAC output from the ignition control, and across terminals 
marked "valve" and "valve gnd".  If no voltage is present, 
replace the ignition control. 
NOTE:  The ignition control contains a safety lockout circuit.  If 
a flame is not detected within 6 seconds after the gas control 
valve is energized, the ignition control will lockout.  To reset, 
turn the power switch "off", wait 45 seconds and switch the 
system "on" to retry ignition. 
 
Gas Control Valves 
Check for 24 VAC supplied to the gas control valves.  If 
voltage is present, the valves should open.  Check for gas 
pressure at the pressure tap, located in the gas piping just 
prior to the burner.  If there is no gas pressure, and the voltage 
is supplied to valves, check piping for obstructions.  If there