kVA
5.0
7.5-10
Width (A)
36”
36”
Depth (B)
24”
24”
Height (C)
80”
80”
Width (D)
N/A
29”
Operates incandescent, magnetic and electronic ballast fluorescent, high power factor compact fluorescent, and high intensity discharge (HID) lamp types.
How to Specify:
LOT Series Uninterruptible Power Supplies
LOT
Page 1 of 2
5 kVA - 10 kVA Single Phase UPS System
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier 
a Genlyte Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC (Lightolier Division) • A0406
Overall Characteristics
• 87% throughput efficiency, 85% emergency efficiency
• Operating temperature range 32°F (0°C) to 104°F (40°C)
• Fault current rating 42kAIC
• Audible noise less than 50dB at 3 ft on “A” weighted scale
• Automatic low battery voltage disconnect
Electrical
• Sine Wave Output
• Double conversion, no interruption
• Voltage regulation ±2%
• Frequency regulation - synchronized to utility, free running 60 Hz, ±0.5%
• Output voltage distortion maximum 3% THD with linear load
• Load power factor capability 0.7 lead to 0.7 lag
• Overload capacity 125% for 10 seconds
• Input power factor correcting to 0.99
• Frequency range 60Hz, ±2.5%
• Input harmonic current distortion <5% THD
• UL 1449, ANSI,IEEE C62, 41 surge suppression
• Completely solid-state Pulse Width Modulation (PWM) inverter
• Internal, make before break maintenance by-pass
• Standard, UL 924 compliant, 90 minute battery backup
• UL 924 auxiliary equipment 10 and 20 minute backup available
• Microprocessor control and diagnostic system
• LCD readout system status panel
• Local 25 even logging/display
• User programmable automatic testing
• Load integrity testing
• Fault annunciating audible alarm
• Current limiting start sequence
• Optional output circuit breakers (OCB) and circuit breakers with trip alarm (OCBA)
• Optional normally off load (NOL) energizes only during power outage, normally off
load with time delay (TDT) also available
Housing
• Free standing, NEMA 1 enclosure
• Seismic anchoring compatible
• Lockable control access panel
Applications
• The solid-state Pulse Width Modulated (PWM) inverter offers enhanced load
compatibility
• Provides conditioned, uninterruptible power for other types of critical loads.
Consult factory for non-lighting load applications.
LOT
SERIES
INPUT
OUTPUT
UNIT
BACK-UP
NOL
OUTPUT
# ON 2ND
# OF NOL
NOL
# OF NOL
VOLTAGE
VOLTAGE
SIZE
DURATION
CKT BRKRS
VOLTAGE
CKT BRKRS
VOLTAGE
2nd VOLTAGE
LOT = Single
Phase
Uninterruptible
Power
Supplies
5.0 = 5.0 kVA
7.5 = 7.5 kVA
10.0 = 10.0 kVA
A = 120 V*
G = 120/240V
J = 277 V
L = 120/208V
0 = None
1 = Yes
T = NOL w/ TDT
00X = Hardwire
01X = 1 OCB
02X = 2 OCB
03X = 3 OCB
04X = 4 OCB
:
:
20X = 20 OCB
------------------
01A = 1 OCBA
02A = 2 OCBA
03A = 3 OCBA
:
:
10A = 10 OCBA
Max. Pole
Spaces 20
00 = 2nd
Voltage
Hardwire or no
2nd Voltage
01
02
03
:
:
19
A = 1
B = 2
C = 3
D = 4
E = 5
F = 6
G = 7
H = 8
I = 9
J = 10
K = 11
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
T = 20
Z = No NOL
1 = First
2 = Second
3 = Both
0 = No NOL
A = 1
B = 2
C = 3
D = 4
E = 5
F = 6
G = 7
H = 8
I = 9
J = 10
K = 11 
L = 12
M = 13
N = 14
O = 15
P = 16
Q = 17
R = 18
S = 19
Z = No NOL
A = 120 V*
G = 120/240V
J = 277 V
L = 120/208V
Y = 120/277V
S = 90 min
X = 10 min
Y = 20 min
(A)
(B)
(C)
Electronics
Cabinet
(D)
Battery
Cabinet
* Not available on 7.5 and 10.0 kVA