Lightwave Communications SCS3230 Manuale Utente

Pagina di 97
ConsoleServer 3200 System  
 
Lightwave Communications 
Rev. A 
- 34 -  
www.lightwavecom.com 
NOT E: 
<ESC> <ESC> or <CTRL>+C will cancel an operation and return to the administrator 
prompt.  Pressing 
<CTRL>+R at the LCI3200> or sys admin> prompt will discard the 
characters on the current command line, and retype the last command used; 
<ENTER> must still 
be pressed to execute the command.  Pressing 
<CTRL>+U at either prompt erases the current 
command line back to the prompt. 
 
6.1  Power-up Sequence and  
Basic Use of the Administrator Functions 
 
NOTE: When the system is first turned on, it may take as long as 90 seconds before the front 
panel display will show any activity, and before the system will 'wake up'. Total boot-up time is 
generally about 3 minutes. 
 
When the SCS3230 is first installed and powered up, it must be configured through the serial 
terminal port.  Connect the terminal port to a terminal device or computer using a terminal 
emulation program.  After the network interface has been configured, the administration login 
may also be reached via telnet.  All the functions available from a local serial connection (with 
the exception of 
BACKUP and RESTORE) are also available through telnet by connecting to port 
5000 of a ConsoleServer’s network IP address.   
 
The serial terminal will display the following text at power-up: 
 
 
ConsoleServer3200 Boot V1.76 
Copyright 2000 by Lightwave Communications, Inc.   All rights reserved. 
Identify Flash 
Flash ID OK 
Verifying Flash Image 
Starting system 
Lightwave Communications, Inc. ConsoleServer3200 
Please wait...system initializing 
Checking non-volatile memory... 
2048 
Start checking and reading stored data 
Reading User Start up ......... 
 
LCI3200>> 
 
 
The power-on self-test may be skipped by pressing 
<ESC> <ESC> or <CTRL>+C, but 
the SCS3230 should be allowed to complete the POST if possible (this check usually 
takes about three minutes).  This information is not available on a network connection, 
as it is not possible to connect to the ConsoleServer via telnet until the power-on self-
test is complete. At the completion of the power-up sequence, the administrator is 
logged out, as indicated by the 
LCI3200>> prompt.  Some commands may be used 
from this prompt, but most are available only when logged in. 
 
NOTE: The administrator may define the system prompt using the 
PROMPT command (see 
section 6.11), but the system default prompt (
LCI3200>>) is used in this guide for clarity.