PROPANE CONVERSION
PAGE 14
PROPANE CONVERSION PROCEDURE
(Only required if Propane gas is used)
This appliance is designed to operate on natural gas, or
propane (LP).  It is factory set for use with natural gas
and requires field conversion for use with propane. The
use of other fuels or combination of fuels will degrade
the performance of this system and may be dangerous.
The conversion kit provided with this appliance contains
components required to convert this appliance from use
with natural gas to use with propane (LP) Gas. All of the
components in the propane conversion kit must be in-
stalled in order for the appliance to operate safely on
propane.
Installation Tools / Supplies
7/16” Open end wrench
Small standard screwdriver
Pipe sealant compound (must be rated for use with
LPG gas)
Parts List
 
Propane RB Regulator conversion screw (Red  indicates
LP gas)
 Burner 
Orifice 
(If you are at an elevation above 4500 feet
do not use the orifice provided in this kit. Contact your
gas supplier to obtain a smaller orifice)
 Pilot 
Orifice
 
Label, Converted to (LP) Propane – Affix to valve
 
Label, Converted to (LP) Propane – Affix to stove body
Avertissement: cet équipement de conversion sera in-
stallé par une agence qualifiée de service confor-
mément aux instructions du fabricant et toutes exi-
gences et codes applicables de l’autorisés avoir la ju-
ridiction.  Si l’information dans cette instruction n’est
pas suivie exactement, un feu, explosion ou production
de protoxyde de carbone peut résulter le dommages
causer de propriété, perte ou blessure personnelle de
vie.  L’agence qualifiée de service est esponsable de
l’installation propre de cet équipment.  L’installation
n’est pas propre et compléte jusqu’à l’opération de
l’appareil converti est chéque suivant les critères établis
dans les instructions de propriétaire provisionnées avec
l’équipement.
IN CANADA:
The conversion shall be carried out in accordance with
the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements of
the CAN1-B149.1 and .2 Installation code.
La conversion devra être effectuée conformément aux
recommandations des autorités provinciales ayant ju-
ridiction et conformément aux exigences du code
d’installation CAN1-B149.1 ET.2.
PROPANE Conversion Procedure
1. Turn off Gas - Turn gas control knob to the off posi-
tion, and shut off the gas supply to the valve. If nec-
essary, disconnect appliance from gas supply.
2. Caution: The gas supply shall be shut off prior to
disconnecting the electrical power, before proceed-
ing with the conversion. Unplug blower power cord.
3. If the installation is at an elevation below 4500 feet,
proceed to step 4. 
If you are at an elevation above 4500
feet, do not use the orifice provided in this kit. Contact your
gas supplier to obtain a smaller orifice).
4. Burner Orifice Installation Procedure:
a. Remove glass door.
b. Remove logs, burner cover, and burner.
c. Use a 7/16” open-end wrench to remove gas
burner orifice.
d. Replace the burner orifice with the appropriate
burner orifice (see instruction #3).
e. Use pipe sealing compound rated for LP gas. BE
VERY CAREFUL THAT THE PIPE COMPOUND
DOES NOT GET INSIDE OF THE ORIFICE
(THIS COULD RESULT IN PLUGGING OF THE
ORIFICE). Using a 7/16” open-end wrench to
tighten orifice - DO NOT OVER TIGHTEN (finger
tight, then 1/2 turn maximum). *Make sure the
orifice is inserted fully into the primary air shutter
fixed opening.
5.
Adjust primary air shutter. Burner Air Shutter open-
ing to be: Natural Gas – 1/2 open, Propane 3/4
open. Some adjustment from standard may be nec-
essary for the desired flame characteristics (see
Burner Flame Appearance, page 15).
6. Replace Pilot Orifice - Using a 7/16” open-end
wrench, remove the pilot burner hood. Replace the
pilot orifice with the one supplied in the propane
conversion kit. Then, reinstall the pilot burner hood.
Ensure that the mark on the pilot hood is lined up