Lennox Hearth 775202M Manuale Utente

Pagina di 4
1
AIR CIRCULATION BLOWER kIT
MODEL VINT-TET BLWR, CAT. NO. 75194
INSTALLATION INSTRUCTIONS FOR AN AIR CIRCULATION 
BLOWER kIT FOR USE WITh ThE VINTAGE™ 27 GAS STOVE
775202M 
Rev. A, 01/2011
LENNOX HEARTH PRODUCTS
KITS AND ACCESSORIES
kIT CONTENTS
1 ea. Blower Assembly (item #1)
2 ea. Washers, #10 (item #2)
2 ea. Nuts, 10-24 Nylock (item #3)
1 ea. Instruction Sheet
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
TURN OFF ThE STOVE AND ALLOW IT TO COMPLETELY COOL BEFORE 
PROCEEDING.
INSTALLATION INSTRUCTIONS
Step 1. Using an allen wrench, remove socket head screw A that secures the 
heat shield to the bottom of the stove. See Figure 2.
Step 2. Using pliers, twist and break off section B of the heat shield (shown 
as hatched section B in Figure 2).  Discard this piece after removing. 
Figure 1 - Kit Contents
Figure 2 
TOOLS NEEDED
5/32” Allen Wrench Or T-Handle Wrench
3/8” End Wrench
Pliers
GENERAL INFORMATION
This optional 150-CFM  blower for the Vintage gas stove provides variable 
speed control, thermal activation and forced air circulation of the warm air 
into the room.
If you encounter any problems, need clarification of these instructions or are 
not qualified to properly install this kit, contact you local distributor or dealer.
Read this instruction sheet in its entirety before beginning the installation.
ALL WARNINGS AND PRECAUTIONS IN ThE INSTALLATION AND OPERA-
TION  MANUAL  PROVIDED  WITh  ThE  APPLIANCE  APPLY  TO  ThESE 
INSTRUCTIONS.
A
B
heat Shield
Stove Bottom
Stove Back
A
B
B
1
2
3
2. Remove Section B
and Discard
1. Remove 
Screw A