Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
LaserTrak Software 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 118 of 221 
Revision A (Sep 2007) 
For example, the Quality Factor that indicates the gauge is measuring a poor 
light scattering surface when the Quality Factor is relatively constant but 
lower then 15.  The Gauge will measure accurately under these conditions 
as long at the QF stays in the yellow and Green areas. 
 
 
 
 
 
When the Quality Factor is jumping from 0 to 15 or from the red to the green 
area quickly, this typically indicates that the product is moving in and out of 
the measuring region of the gauge or there is something interfering with the 
Laser beams hitting the surface of the material being measured. The gauge 
can not make measurements if the Laser beam does not have a clear path 
between the gauge and the surface being measured. This would be indicated 
by a Quality Factor equal to zero or in the red zone on the bar graph. 
Length Mode Display 
 
 
 
 
 
 
 
 
 
 
The Length Mode Screen Has two modes of operation, the Successive 
Reading mode and Final Length mode. Successive Reading mode allows 
discrete lengths to be measured and displayed in the form of a Histogram. 
The software will acquire the final length measured after the length counter 
has remained at the same length for 4 successive User Update Periods. This