Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Appendix E: Troubleshooting Guide 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 214 of 221 
Revision A (Sep 2007) 
 
Poor Quality Factor, or won't 
measure on twinner line 
Too close to twinner 
Move gauge farther from twinner to a 
location where the wires aren't spinning. 
 
There is no laser coming out of 
the gauge 
Something is blocking the 
laser, the beam shutter is 
closed, or the laser interlock 
is open. 
Verify that the Power LED is on, and that 
the LASER ON LED is on. 
 
Verify no laser by blocking the beam 
with a white business card or IR 
detector. 
 
Use LaserTrak to verify the following: 
•  Laser Interlock is closed 
•  Beam Shutter interlock is closed. 
•  Laser At Temp 
 
Verify that nothing is covering the 
gauge's optical window. 
 
The valid light turns off after I 
change a setting. 
Valid light is indicating serial 
port framing. 
This is normal.  When you change 
settings that affect measurements, or 
when you change one of the baud 
rate/framing settings, the gauge will re-
indicate the current baud rate settings.  
The COMM light flashes to indicate the 
baud rate setting, and the Valid light 
turns on or off to indicate the framing.  
When the valid light is off while the 
COMM light is indicating the baud rate, it 
indicates that the serial port is 
configured for 7n2 framing.  See the 
Baud Rate Indication
 setting for details. 
 
 
Measurements 
 
Non accurate length 
measurements when using final 
length measurement. 
Starting and Ending length 
correction disabled 
 
Product poorly guided 
 
 
 
Not using external optical 
switches 
 
External optical switches 
misaligned 
Set Material Present dropout time to a 
value > 0. 
 
Presenting each part to the 
measurement system consistently is 
critical. 
 
Install external optical switches. 
 
 
1.  Verify that the optical switches are 
properly aligned.