Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Installing the System 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 31 of 221 
Revision A (Sep 2007) 
Maximizing Performance
 
The system is now at the point where it can be powered on and the laser 
activated so beams are emitted from the front of the gauge. Be sure that the 
laser interlock and shutter control circuits are functioning properly. 
  When Pin 16 is connected to GND (Pin 11, 19, or 21), the laser 
becomes operational. 
  When Pin 17 is connected to GND (Pin 11, 19, or 21), the shutter will 
open. 
  Check the key switch to verify the laser power can be controlled. 
Warning:   Avoid exposure to the beam. Never look directly into the laser 
beams, even when wearing protective eyewear. Eye damage 
could result. 
Note:   There may be some delay time between when the system is powered 
on, and when the laser comes on.  There is a 7 second delay after 
power is applied to the laser (key switch on, laser interlock closed) 
before the laser turns on.  The laser will also not turn on until the 
laser temperature controller stabilizes.  This may take a few minutes 
after power is initially applied.  The standoff distance can be verified 
by using a business card or sheet of white paper.  Both beams can 
be viewed and the area where the beams overlap is the active 
measurement region.  The location where the overlap of the beams is 
smallest is the center of the measurement region.  This location 
corresponds to the standoff distance and is where the beams should 
intersect the product. 
The configuration and setup of the gauge can be verified and/or changed 
using the supplied LaserTrak Software or directly using the serial commands 
listed in the 
Communication Protocol
 section.  Utilizing either one of these 
approaches requires a computer with an RS-232 serial port connected to pins 
1 and 2 of the 25-pin D-sub connector, or an RS-422 serial port connected to 
pins 1-4 of the 9-pin D-sub connector. 
Once proper communication is established (see the See the LaserTrak 
Software section for help), it is recommended to check the Quality Factor (QF). 
QF can be checked using LaserTrak, and viewing the chart recorder screen.  If 
it is below 15, try to move the product or the gauge slightly (adjust the 
standoff) and look for improvements in QF.  Once QF is maximized, change 
the line speed and look for a corresponding velocity change on the chart 
recorder.