Quick Start Guide
  
INSTEON
® 
OutletLinc™ On/Off Outlet 
Model: 2473S 
 
Tools Needed 
• 
Flathead screwdriver 
 
•     Phillips screwdriver 
• 
Wire cutter/stripper 
 
•     Voltage tester 
 
Installing OutletLinc 
Installation should only be performed by a qualified electrician or a homeowner who is 
familiar and comfortable with electrical circuitry. If you have questions, consult an electrician 
or call the INSTEON Support Line at 866-243-8022 
1) 
At the circuit breaker or fuse panel, disable circuit supplying power to outlet 
2) 
Remove existing outlet and wallplate 
3) 
Disconnect wires from existing outlet and ensure you have ½” of bare wire on the ends 
4) 
Enable power to the outlet, then use voltage meter to identify line, neutral and ground 
wires. Once wires are identified, turn off circuit breaker. 
5) 
Twist OutletLinc ground wire (bare copper) to outlet ground wire with included wire nut 
6) 
Twist OutletLinc neutral wire (white) to outlet neutral wire with included wire nut 
7) 
Twist OutletLinc line wire (black) to outlet line wire with included wire nut 
8) 
After ensuring all wire connectors are firmly attached and that there is no exposed copper (except for ground wire), carefully 
place OutletLinc into wall box and replace wallplate 
9) 
Turn on circuit breaker 
10) 
Plug lamp, appliance or other device you want to control (load) into OutletLinc top outlet 
11) 
Test by tapping OutletLinc Set button a few times 
Connected light/load will turn on and off
 
 
Make OutletLinc a Responder 
Control OutletLinc from another INSTEON device: 
1) 
Put controller into linking mode.* (For most controllers press and hold Set button for 3 seconds or an on/scene button for 10 
seconds.) 
2) 
Turn on load plugged into OutletLinc 
3) 
Press and hold OutletLinc Set button for 3 seconds 
 
 
Status LED will flash, then turn on solid  
4) 
Confirm link by tapping controller’s button on and off  
 
 
Connected light/load will turn on and off
 
 
Owner’s Manual and Tech Support 
For the complete Owner’s Manual and the most up-to-date Quick Start Guide visit
Call: INSTEON Support Line at 866-243-8022 
 
 
*Linking mode will time out after 30 seconds 
Set 
button
 
INSTEON controlled 
on/off receptacle
 
Status 
LED
 
Always-on uncontrolled 