INSTEON 2413S Dépliant

Pagina di 1
 
2413S Rev. 7/20/2012 11:40 AM / See Owner’s Manual for Warranty Information. 
Protected under U.S. and foreign patents (see www.insteon.com
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845 
 
 
Quick Start Guide
  
PowerLinc Modem
TM
 – INSTEON
®
 
Serial Interface (Dual-Band) 
Model: 2413S
 
Install PowerLinc Modem 
1)  Ensure PowerLinc Modem is not plugged into your computer 
2)  Plug PowerLinc Modem into an AC wall outlet 
3)  Plug clear end of included DB-9 serial cable into PowerLinc Modem’s interface port 
4)  Plug black end of cable into an available serial port on your PC 
PowerLinc Modem is now ready
 
Connector Specifications 
 
 
 
Communications 
Pin 1: RS232 to PC pin 2 (Rx) 
Pin 2: Not connected 
Pin 3: TTL output (from PLM) 
Pin 4: Not connected 
Pin 5: Not connected 
Pin 6: TTL input (from PLM) 
Pin 7: Common ground 
Pin 8: RS232 from PC pin 3 (Tx) 
 
Tips for Using PowerLinc Modem 
 
Do not use a serial cable longer than 10’ (6’ or less is recommended) 
 
Do not plug PowerLinc Modem into a power strip or AC line filter 
 
Use only one PowerLinc Modem per computer 
 
Do not place near large metal objects, such as refrigerators or TVs 
 
Some computers and their accessories can absorb PowerLinc Carrier (PLC) signals off the powerlines. Since PowerLinc 
Modem will be close to the computer, the power strip for the computer should be filtered. Use an INSTEON FilterLinc (#1626-
10) on the computer’s power strip to keep PowerLinc Modem signals from getting absorbed by the computer equipment 
 
If computer’s serial port is shared with another hardware device (scanner, PDA, etc.) be sure to turn off that device’s program 
on the PC. If left running, the home automation software will not be able to communicate with PowerLinc Modem. 
 
To reset PowerLinc Modem to its original factory settings, unplug from wall outlet and wait 10 seconds. Press and hold Set 
button; while continuing to press and hold, plug back in. A long beep will sound; continue holding Set button until beep stops, 
then release. 
 
After several seconds, status LED will turn on to indicate reset is complete 
 
Use PowerLinc Modem as a Phase Bridge 
1)  Install additional dual-band INSTEON devices if they are not already installed 
2)  Start Phase Detection Mode by tapping the Set button on PowerLinc Modem four times quickly 
PowerLinc Modem will begin beeping and status LED will turn on solid green  
3)  Check the LED behavior of the other dual-band devices to see if they are on the opposite phase 
If at least one of the dual-band device LEDs is blinking green or is bright solid white or blue, the device is on the opposite 
phase. Continue on to step 4.
 
If none of the dual-band devices exhibit the behavior above, they are on the same electrical phase. Try the following:  
 
Follow steps 2 and 3 with the other dual-band devices to see if they are exhibiting the desired LED behavior 
 
Move a dual-band device to another location until it exhibits the desired LED behavior 
4)  Tap PowerLinc Modem Set button 
PowerLinc Modem will stop beeping 
 
Owner’s Manual and Tech Support 
Owner’s Manual and current Quick Start Guide
Call: INSTEON Support Line at 800-762-7845 
 
This device complies with FCC Rules Part 15.Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or 
that may cause undesired operation. The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does 
cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: 
• Reorient or relocate the receiving antenna of the device experiencing the interference. 
• Increase the distance between this device and the receiver. 
• Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver. 
• Consult the dealer or an experienced radio/TV technician. 
WARNING!
 Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 
Interface Port 
 
The RS 232 serial communications to PowerLinc 
Modem are: 
19,200 baud 
8 data bits 
No parity 
1 stop bit 
 
NOTE: each byte sent to PowerLinc Modem will be 
echoed back to the host. 
Interface Port 
 
Set button