Infocus PN-L702B Manuale Utente

Pagina di 46
Page 44
OTHER MENU
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
Screen Size (PC)
WIDE
WR
1-5
1-5
1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
Screen Size (AV)
WIDE
WR
1-5
1-5
1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
Volume
VOLM
WR
0-31
0-31
Mute
MUTE
WR
0-1
0-1
0: OFF, 1: ON
-
Information
Model
INF1
R
Value
Serial No. SRNO
R
Value
Bright
VLMP
WR
0-31
0-31
Temperature Sensor
DSTA
R
0
Internal temperature normal
1
Internal temperature abnormal (Standby mode)
2
Internal temperature abnormal (Temperature is normal now, but it was 
abnormal during operation.)
3
Internal temperature abnormal (Brightness of the backlight decreases.)
4
Temperature sensor abnormal 
Temperature Aquisition
ERRT
R
Value
Temperature at temperature sensors 1 through 3 are returned in the fol-
lowing forms:
[Sensor 1], [Sensor 2], [Sensor 3]
Indicates a temperature sensor abnormality when “126” is returned.
Cause of Last Standby 
Mode
STCA
W
0
Initialization
R
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the monitor power switch
3 Standby mode by RS232C or LAN
4 Waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
COMMANDS FOR SETTING THE GAMMA USER DATA
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
Red Gamma Data Transfer
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
aa: 01-16
xxxx: 0000-1023
cc: 00-FF
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and 
user data
Green Gamma Data Transfer
UGGW
W
Blue Gamma Data Transfer
UGBW
W
Red Gamma Data Read
UGRR
W
1-16
xxxx ··· xxxx
(xxxx: 32 pieces)
xxxx: 0000-1023
xxxx: User data of 32 pieces
Green Gamma Data Read
UGGR
W
1-16
Blue Gamma Data Read
UGBR
W
1-16
User Data Intialize
UGRS
W
0
Initialize the user data.
User Data Save
UGSV
W
0
Save the user data in the monitor.