• Typical installation example
A UHF base station transmitter is to be installed on 
the roof of an office.
The transmit power is 25 watts, there is 20 m of 
RG-213 coaxial cable and the antenna is vertically 
polarised dipole.
The specification of the RG-213 cable gives a loss 
of 1.5 dB/10 m. There will be 3 dB loss for the 20 m 
length used.
The RF power at the antenna input will be 12.5 watts.
The dipole antenna has a forward gain of 0 dBd or 
1.6, giving an EIRP of 20 watts.
Referring to the table above for VHF/UHF vertical 
antennas, this gives a front clearance distance of ap-
prox. 1.5 m and a height clearance of 3 m.
The antenna installation needs to ensure that the low-
est part of the antenna is at least 3 m above any point 
where the general public may gain access and that 
they cannot pass within 1.5 m in front of the antenna.
If there is no general public access to the roof in 
question then the antenna could be mounted on a 
short stub mast. If there is such access to the roof 
then the antenna could be mounted on top of a short 
mast of 3.2 m high. The mast position should be such 
that the antenna can radiate clearly i.e. no other ob-
ject or structure is within 1.5 m (preferably more).
It should be relatively easy to fulfil all these recom-
mendations. 
If for any reason such minimum distances are impos-
sible to guarantee then some type of access con-
trol fence or barrier around the antenna installation 
should be provided.
Should a Yagi type antenna be used then you will 
have to obtain a 3 dimensional polar plot of the radia-
tion characteristic from the manufacturer and evaluate 
the clearance distances in both vertical and horizontal 
planes.
• Operating Notes
All of the above comments on RF safety assume that 
the radio is transmitting continuously in a constant 
carrier mode such as FM or RTTY etc.
The RF exposure limits recommended by the EC are 
based on the mean power averaged over a 6 minute 
period.
Therefore if the total transmit time during any 6 
minute period is reduced, then the installation will be 
even further within the recommended limits.
CE Versions of the IC-FR5100/IC-FR6100 
which display the “CE” symbol on the serial 
number seal, comply with the essential re-
quirements of the European Radio and 
Telecommunication Terminal  Directive 
1999/5/EC.
This warning symbol indicates that this 
equipment operates in non-harmonised 
frequency bands and/or may be subject to 
licensing conditions in the country of use. 
Be sure to check that you have  the correct 
version of this radio or the correct pro-
gramming of this radio, to comply with na-
tional licensing requirement.
• List of Country codes (ISO 3166-1)
  1  Austria 
AT
  2  Belgium 
BE
  3  Bulgaria 
BG
  4  Croatia 
HR
  5  Czech Republic 
CZ
  6  Cyprus 
CY
  7  Denmark 
DK
  8  Estonia 
EE
  9  Finland 
FI
 10  France 
FR
 11  Germany 
DE
 12  Greece 
GR
 13  Hungary 
HU
 14  Iceland 
IS
 15  Ireland 
IE
 16  Italy 
IT
 17  Latvia 
LV
 18  Liechtenstein 
LI
 19  Lithuania 
LT
 20  Luxembourg 
LU
 21  Malta 
MT
 22  Netherlands 
NL
 23  Norway 
NO
 24  Poland 
PL
 25  Portugal 
PT
 26  Romania 
RO
 27  Slovakia 
SK
 28  Slovenia 
SI
 29  Spain 
ES
 30  Sweden 
SE
 31  Switzerland 
CH
 32  Turkey 
TR
 33  United Kingdom 
GB
 
Country 
Codes  
Country 
Codes