Pagina di 270
2. Start the DS4000 Storage Manager client software. The Enterprise Management
window opens.
3. Add the DS4000 subsystem to the DS4000 Enterprise Management domain
using the default IP addresses.
4. In the Enterprise Management window, click on the name of the default storage
subsystem. The Subsystem Management window opens.
5. In the Subsystem Management window, right-click the controller icon and select
Change —> Network Configuration in the pull-down menu. The Change
Network Configuration window opens.
6. In the Change Network Configuration window, click on the Controller A and
Controller B tabs and type the new TCP/IP addresses in their appropriate fields.
Click OK.
7. Close the Subsystem Management window, wait at least five minutes, then
delete the default DS4000 storage subsystem entry in the Enterprise
Management window. The default DS4000 storage subsystem entry still
displays, but shows an “unresponsive” icon.
8. If applicable, change the IP address of the Ethernet port in the management
station to a value that is on the same TCP/IP subnet as the controller Ethernet
port IP addresses that you just assigned. Exit DS4000 Storage Manager, then
restart.
9. Add a new storage subsystem entry in the Enterprise Management window,
using the new assigned IP addresses.
Note: To manage storage subsystems through a firewall, configure the firewall to
open port 2463 to TCP data.
AC power supply and fan units
The DS4700 Express Storage Subsystem (models 70A, 70H, 72A, and 72H) has
two removable ac power supply and fan units. Each power supply and fan unit
contains one power supply and two fans. The four fans pull air through the drive
from front to back across the drives.
The fans provide redundant cooling, which means that if one of the fans in either
fan housing fails, the remaining fans continue to provide sufficient cooling to
operate the storage subsystem. The power supplies provide power to the internal
components by converting incoming ac voltage to dc voltage. If one power supply is
turned off or malfunctions, the other power supply maintains electrical power to the
storage subsystem. To preserve the optimal airflow, do not remove a failed power
supply and fan unit CRU from the DS4700 Express chassis until you are ready to
replace it with a new CRU.
Figure 4 on page 13 shows power supply and fan unit components for the DS4700
Express model 70 and Figure 5 on page 13 shows power supply and fan unit
components for DS4700 Express model 72.
Note: Although both power supply and fan units (left and right) are identical, they
are seated in the DS4700 Express chassis in opposite orientations. If the
power supply and fan unit cannot fully be inserted in the power supply and
fan unit bay, flip it 180 degree and reinsert it.
12
IBM System Storage DS4700 Express Storage Subsystem: Installation, User’s and Maintenance Guide