Repair
309293J
51
Atomizing Air Restrictor Valve 
Removal and Replacement
1.
Prepare the gun for service, page 41.
2.
Remove the atomizing air restrictor valve (23). 
Inspect the o-ring (23c*). Replace if necessary. See 
F
3.
Install a new atomizing air restrictor valve (23), or 
disassemble and replace parts individually. The 
valve protrusion must be oriented to clear the air 
valve (21) shaft.
If the atomizing air restrictor valve is not desired, install 
the supplied plug (47).
4.
Torque the valve housing (23a) to 15-20 in-lb 
(1.7-2.3 N•m).
Fig. 34. Atomizing Air Restrictor Valve
ES ON/OFF Valve Repair
1.
Prepare the gun for service, page 41.
2.
Loosen the screw (48). Remove the valve. 
3.
Lubricate the o-rings (22a* and 22b*) with non-sili-
cone grease, Part No. 111265. Do not over-lubri-
cate. 
4.
Clean and inspect parts for damage. Replace if nec-
essary. 
The protrusion on the retainer plate (22d) must point 
upward.
5.
Reinstall the valve. Torque the screw (48) to 15-25 
in-lb (1.7-2.8 N•m).
Fig. 35. ES ON/OFF Valve
TI1686A
23b
23a
23d
47
23c*
CAUTION
Do not over-lubricate parts. Excessive lubricant on 
the o-rings can be pushed into the gun air passage 
and blemish the finish on the workpiece.
TI1488A
22a*
22b*
22c
22d
22e
22f
22g
48