7
Maximum Frame Loading
 Chapter 1: Introducing the 6800/7000 Series of Frames
Maximum Frame Loading
There is a limit on the amount of total module power consumption 
(excluding the power supply) allowable within a given frame. These 
limits are based on the ability of the unit to dissipate heat over a specified 
operating temperature range.
Frame
Power 
Supply
Qty. +ve (W)
-ve (W)
Total 
(W)
Frame Heat
Dissipation
FR-7000MB
7000PS
1
3.75 W
3.75 W
7.5 W 4 W
FR-6801 or 
FR-7001
6801PS
1
22 W
22 W
44 W
20 W
FR-6801-1
6804PS-1
1
78 W
29 W
107 W 20 W
FR-6801-1-48 6801PS-48
1
22 W
22 W
44 W
20 W
FR-6802
6801PS
1
22 W
22 W
44 W
35 W
6801PS
2
22 W
22 W
44 W
30 W
FR-6804-(1) 
with CF-6801 
connected
6804PS-1
1
78 W
29 W
107 W 75 W
6804PS-1
2
78 W
29 W
107 W 75 W
FR-6804(-1) 
without 
CF-6801 
connected
6804PS-1
1
78 W
29 W
107 W 40 W
6804PS-1
2
78 W
29 W
107 W 40 W
FR-6804-1-48 
with CF-6801 
connected
6804PS-1-48 1
78 W
29 W
107 W 75 W
6804PS-1-48 2
78 W
29 W
107 W 75 W
FR-6804-1-48 
without 
CF-6801 
connected
6804PS-1-48 1
78 W
29 W
107 W 40 W
6804PS-1-48 2
78 W
29 W
107 W 40 W
If the total loading exceeds 
either the power supply 
limitations or the maximum 
frame loading limited, then that 
frame configuration is not 
recommended.
The 6801PS (Power Supply) 
should not be used in the 