 Chapter 3: FR-6804/FR-6804-1 Frames
Overview
12
6800/7000 Series - Frames and Power Supplies Installation and Operation Manual
The GPI is made up of two parts: 
A fault sensing circuit within each power supply that monitors the 
primary circuit and the two output voltages. 
A relay that provides isolation between Leitch equipment and the 
GPI output connector at the rear of the frame. 
There are three connections provided for GPI reporting: 
Normally  closed  (NC)
Normally open (NO) 
Ground
To comply with SMPTE standards, the product uses the NC output and 
ground. The relay has two states for GPI reporting:
OPEN: 
An open output signifies that the GPI relay is activated and the 
power supplies in the frame are present and operating correctly.
CLOSED:
 A closed output signifies that the GPI relay has been
de-activated indicating an internal fault in either of the power 
supplies or a loss of power to one or both of the supplies.