This section gives a series of checks to be carried out on the dryer before starting for the first time in
the drying season.  If any of the checks fail to produce the stated result, you should consult your dealer.
YOU SHOULD NOT ATTEMPT TO USE THE DRYER UNLESS ALL THE PRE-START CHECKS
HAVE BEEN SUCCESSFULLY COMPLETED.
BEFORE ATTEMPTING TO OPERATE THE DRYER MAKE SURE
ALL SAFETY SHIELDS ARE IN PLACE, ALL BOTTOM CLEANOUT
AND REAR ACCESS DOORS ARE CLOSED AND ALL PERSONNEL
ARE CLEAR OF THE DRYER
Open all metering roll access doors and inspect each compartment for any bolts, nuts or other foreign material,
that may cause possible jamming of the metering rolls.
INSPECT THE METERING ROLLS
ELECTRICAL POWER
Turn on the electrical power supply to the dryer, set all circuit breakers to on, including the safety disconnect
handle mounted on front of the dryer power panel.
CONTROL POWER SWITCH
Turn the control power switch to on.  The switch will light up. A copyright message, model number, total running
time in hours and minutes, current date and time will appear.  At this point the controller will lock out all other dryer
functions.  Once the date and time appear, press the
button and the dryer will perform a safety circuit
check. If a fault is found, the cause will be displayed on the LCD.  If all are found safe, the controller will supply
power to the electronic fuel shut-off valve (Maxon), if so equipped, and the drying mode switch will light up, indicat-
ing that the dryer is ready to be started.
RUN BUTTON
Push the dryer run button, and all the selector switches on the control panel will be activated.
FUEL CHECK
If using LP gas, make sure the tank has plenty of fuel and that the tank must not have a regulator mounted on the
liquid line. Slowly open the main fuel supply valve at the tank. Then, open the electronic shut off valve (Maxon
valve), if so equipped, or open the manual shut off valve on the dryer to allow fuel flow to the dryer.
If using natural gas, make sure an adequate supply is available. Turn on the valve  along the supply line. Then,
open the electronic shut off valve (Maxon valve).  Inspect all gas lines and connections for possible leaks.
Any gas leaks must be fixed immediately!