On this screen you can disable a fan and heater out of the Network loop.  This would be used if you have a fan/
heater computer that is malfunctioning and rather than preventing you from using the dryer at all, you can just
ignore it.  So you can continue to use your dryer until you can have the dryer serviced.  To change the fan/heater to
an inactive state, press the
buttons to toggle between active or inactive.  Then press the
button to accept your changes.
IMPORTANT NOTE! 
It is possible to change all your fan and heaters to an inactive state which would
cause your dryer to be unable to dry grain.
The display screen will then advance to the next fan and heater on your dryer.  You can easily configure your dryer
to use both On/Off burners and Hi/Lo burners at the same time. This depends on your particular drying situation.
Possible reasons for using On/Off burner:
Low drying temperatures needed (ie. drying popcorn, rice, soybeans)
Very warm outside ambient temperatures
Drying grain that already has low moisture content requiring only 1 to 5 point moisture removal
May help prevent Vapor High Limit shutdowns
Possible reasons for using Hi/Lo burner:
Higher drying temperatures needed (ie. Hard to dry varieties of corn)
Colder outside ambient temperatures
High moisture content grain requiring 5-15 point removal
SET TIME & DATE
Use this screen to set the computers time and date.  The time and date is preset at the factory but because of
different time zones you may find the need to change it.  Just press the
button to advance to the
number on the line that needs to be changed or you can use the
button to back up to the previous
number on the line. Use the
to change the number directly above the flashing cursor. Once
you are satisfied with your changes press the
button to accept them.