GSI Outdoors PNEG-338 Manuale Utente

Pagina di 32
PNEG-338 Portable Dryer Installation Manual
23
10. Electrical Load Information
 provide information for the electrician wiring the grain dryer and are a reference 
guide for parts. You should contact the local power company and have a representative survey the 
installation to see that the wiring is compatible with their system and that adequate power is supplied to 
the unit. Remember that the only thing connected to the recommended service amps should be the 
grain dryer.
Adhere to all electrical safety practices and codes. (Refer to the National Electrical Code Standard 
handbook by the National Fire Protection Association). A qualified electrician must make all electrical 
wiring installations. 
Dryer 
Model #
Voltage
Motor
HP
Fuel Load 
Amps
Maximum Amps 
with Auxiliaries
Minimum 
Amps
Recommended 
Service in Amps
Branch Breaker 
in Amps
1108
1 PH 230V
Top Auger
1.5
8
153
62.5
200
60
Bottom Auger
1
6.5
60
Fan
10 to 12
48
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
1.5
5
104
41.4
150
50
Bottom Auger
1
3.4
50
Fan
10 to 12
33
60
(2) Auxiliary
(2) 7.5
40
*
3 PH 440V
Top Auger
1.5
2.5
57
20.7
150
60
Bottom Auger
1
1.7
60
Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 7.5
20
*
1110
1 PH 230V 
Top Auger
2
14
162
70
225
60
Bottom Auger
1.5
8
60
Fan
10 to 12
48
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V 
Top Auger
2
6.2
101
39.2
150
50
Bottom Auger
1.5
5
50
Fan
10 
28
60
(2) Auxiliary
(2) 7.5
40
*
3 PH 440V
Top Auger
2
3.1
56
19.6
150
60
Bottom Auger
1.5
2.5
60
Fan
10 
14
60
(2) Auxiliary
(2) 7.5
20
*
1112
1 PH 230V
Top Auger
2
14
196
100
300
60
Bottom Auger
1.5
8
60
Fan
10 to 17
78
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
2
6.2
114
50.2
175
50
Bottom Auger
1.5
5
50
Fan
15
39
60
(2) Auxiliary
(2) 7.5
40
*
3 PH 440V
Top Auger
2
3.1
62
25.1
150
60
Bottom Auger
1.5
2.5
60
Fan
15
19.5
60
(2) Auxiliary
(2) 7.5
20
*
*Auxiliaries run through load and unload breakers.