GE SX TRANSISTOR CONTROL IC3645SR4U404N2 Manuale Utente

Pagina di 74
ADJUSTABLE FEATURES 
TRANSISTOR PUMP CONTROLS 
 
 
Page 66  
 
August 1999 
 
switch input signal is received by the control card.  SL3 
limit switch is a normally open switch connected to battery 
negative, the switch closing enables speed limit. 
 
Range   
0% to 100% battery volts 
Setting   
0 to 255 
Resolution 
0.375 volts per set unit 
 
Example: Setting of 50=18.75 volts  
 
FUNCTION 52: 
MODE 2 - CONTROLLED ACCELERATION 
 
(Push CONT 5) 
 
 
Same as function 48. 
 
FUNCTION 53: 
MODE 2 - SPEED LIMIT 2 (SL2) 
 
(Push CONT 6) 
 
Same as Function 49. 
 
FUNCTION 54: 
MODE 2 - SPEED LIMIT 3 (SL3) 
 
(Push CONT 7) 
 
Same as Function 50. 
 
FUNCTION 55:   NOT APPLICABLE 
 
 
This function is not applicable to this type of control and 
should not be adjusted. 
 
FUNCTION 56: 
MODE 3 - CONTROLLED ACCELERATION  
 
(Push CONT 9) 
 
Same as function 48. 
 
FUNCTION 57: 
MODE 3 - SPEED LIMIT 2 (SL2) 
 
(Push CONT 10) 
 
 
Same as Function 49. 
 
FUNCTION 58: 
MODE 3 - SPEED LIMIT 3 (SL3) 
 
(Push CONT 11) 
 
Same as Function 50. 
 
FUNCTION 59:   NOT APPLICABLE 
 
 
This function is not applicable to this type of control and 
should not be adjusted. 
 
FUNCTION 60: 
MODE 4 - CONTROLLED ACCELERATION  
 
(Push CONT 13) 
 
Same as function 48. 
 
 
FUNCTION 61: 
MODE 4 - SPEED LIMIT 2 (SL2) 
 
(Push CONT 14) 
 
 
Same as Function 49. 
 
FUNCTION 62: 
MODE 4 - SPEED LIMIT 3 (SL3) 
 
(Push CONT 15) 
 
Same as Function 50.