Conversion to LP Gas
Servicing  -  warning
This conversion must be performed by a competent 
person. After conversion the installation must comply 
with the relevant regulations and also the local 
electricity supply company requirements. Read the 
instructions before converting this appliance.
Failure to convert the appliance correctly could 
invalidate any warranty or liability claims and lead to 
prosecution.
This instruction must be used in conjunction with 
the rest of the appliance instruction, in particular 
for information on Standards, cooker positioning, 
connection hose suitability etc.
When servicing or replacing gas-carrying components 
disconnect from gas before commencing operation and 
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Conversion
Disconnect from electricity and gas before servicing. 
Check appliance is safe when you have finished.
This appliance is CAT II 2H3+. It is supplied set for G20 
natural gas at 20millibar
A conversion kit for LP gas is supplied with the cooker.
Injectors
Remove pan supports and burner heads. 
Burner head
   
Brass venturi
Burner base
Burner ring
Undo the large brass nuts and remove the brass venturis 
and brass rings.
Either:
Use a long box spanner to access and remove the 
old jets.
Or:
Lift up the front of the hotplate top and prop it 
up. The burner bases are now accessible - remove 
the old jets.
Save the jets removed from the appliance for possible 
future use. Fit the new jets, see the table  for the correct 
type.
If you have lifted up the hotplate then carefully 
replace it taking care not to damage or displace the 
ignition electrodes or flame safety probes (arrowed) 
and replace the rear fixing screws.
To  convert  the  control  taps
Pull off all the control knobs.
Open the oven door & grill door and remove the fixing 
screws underneath the control panel.
Remove the 3 fixing screws at the top of the control 
panel.
Pull the control panel forward. Rest it on the open grill 
door and the open right hand oven door
The tap bypass screw is now accessible. Unscrew the tap 
bypass screw. 
Using a pair of long nose pliers carefully remove the 
bypass screw and fit the correct replacement screw. See 
table for correct size. Tighten the screw down.
Repeat for all the burner control taps.