The -48VDC terminal block on the Magnum 6K16-Series Switch, as shown in Fig C5.0 
is located on the left front of the unit and is equipped with  
five (5) screw-down lead  
posts. The primary terminals are identified as positive (A+), negative  
(A-), and the secondary power terminals as negative (B-), positive(B+).  The chassis 
“earth” or ground (GND) is a threaded post with a #6 nut.  The Dual Source terminal 
block for the 24VDC and 125VDC are similar. 
 
 Figure C5.0:  -48VDC Dual-Source, wiring connections to the External  
Terminal Block on a Magnum -48VDC with Dual-Source option 
 
Note: The GND should be hooked up first. The 6K16-Series unit has a floating ground, 
so the user may elect to Ground either + or = terminal to suit the customer’s use. 
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC,  
always use a digital voltmeter to measure the output voltage of the power supply and 
determine the lead which is  more  “+ve potential”. The more “+ve” voltage lead from 
48V  or –48V supply must be connected to the post labeled “+”. 
 
 
The connection procedure is straightforward. Simply connect the DC leads to 
the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground 
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely 
tightened.  
 
The 24VDC & 125VDC terminal block on Magnum 6K16-Series’s is similar to 
that described in the –48VDC information above.
 
C5.1  UL Requirements 
 
The following must be adhered to in order to conform to UL requirements: 
1.   Minimum 18 AWG cable for connection to a Centralized DC power source. 
2.   Minimum 14 AWG cable for connection to earthing wiring. 
3.   Use only with Listed 10 A circuit breaker provided in building installation. 
4.   
“Complies with FDA radiation performance standards, 21 CFR subchapter J.” 
or equivalent. 
5.   Fastening torque of the lugs on the terminal block:  9 inch pound max. 
6.   Centralized DC Power Source cable securement, use at least four cable ties to 
secure the cable to the rack at least 4 inches apart with the first one located 
within 6 inches of the terminal block.
 
C6.0 ORDERING 
INFORMATION 
 
To order the optional Dual-Source -48VDC power supply factory installed, 
order “Dual-Src48V” as a separate line item following the product model. 
 
    Example: Magnum 6K16-SeriesR-48VDC  
 
 
  Dual-Src-48V   for the regular DS model with no ON-OFF switch 
 
             or    Dual-Src48V-SWITCH   with the ON-OFF manual switch. 
 
 
Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a 
separate line item following the product model.  
  
Example: 
Magnum 6K16-SeriesR-24VDC or Magnum 6K16-SeriesR-
125VDC 
  
 Dual-Src24V 
for regular models with no ON-OFF switch 
   
Or Dual-Src125V-Switch for models with the ON-OFF switch 
 
 
C7.0 
OPERATION   
 
 
Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC 
Switch models are identical to that of the standard models.