ETA Systems Impact Driver ETA-S20RT Manuale Utente

Pagina di 12
 
– 10 – ETAsys.com
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
ETA-S20RT 
AC Distribution & Suppressor Unit
SPECIFICATIONS
Type
Power Conditioner & Suppressor
Load Rating 
20A
Safety Listings  
ETL (UL 60065 Standard)
Front Panel
Outlets 
  1  Unswitched
USB Port
1 USB Charge/Light Port (5VDC, 1A)
Activation  Switch 
  Rocker
Circuit Breaker
20A Resettable
Indicators 
AC Power On, AC Fault, EVS Protect
Rear Panel
AC Outlets 
  8 Outlets Total
LED Light Socket
XLR Socket to Provide 12VDC for Optional AP-GNL18 Gooseneck Lamp
LED Light Switch 
  Two position (On / Off)
Remote Activation 
  Latching Type Dry Contact Closure or 5V-24VDC
Remote Activation Connector 
4 Position 3.5mm Phoenix Type Connection
AC Mains Power Cord
9' (2.74m), 12 Gauge, 20A Male AC Plug
Technical Data
Current Rating  
  20 Amps
Operating Voltage 
  102VAC - 132VAC
Power Consumption  
8 Watts
Min. Spike Clamping Voltage
460VRMS @ 3,000A
Max. Spike Clamping Voltage 
  6000V
Max. Spike Clamping Resp. Time
1 Nanosecond
Spike Clamping Voltage @ 100A
1250Vp for 20µs
Maximum Surge Current  
6,500A
Energy Rating @ 2ms
600 Joules
Noise Attenuation RFI
10dB @ 10kHz / 40dB @ 100kHz / 100dB @ 10MHz
EVS Limits 
95VAC Low, 140VAC High, Auto Reset
Temperature Range 
5° – 35°C
Humidity Range 
5% to 95% Relative Humidity
Mechanical
Chassis Finish
Black
Mounting 
Rack Mount, 1 RU
Height 
  1.75"  (1RU,  44.5mm)
Width 
  19"  (482.6mm)
Depth 
8" (203mm)
Weight 
5.5 lbs (2.49kg)