ISP1760; ISP1761 Win CE 5.0 User Installation Guide
Remark: The ISP176x denotes the ISP1760 and ISP1761 Hi-Speed Universal Serial Bus 
controllers, and any future derivative. 
1.  Introduction 
This document describes the Platform Builder setup for the ISP176x Universal Serial Bus 
(USB) Host Controller Driver (HCD). The document covers the installation of software for 
the ISP176x on the Microsoft Windows CE platform Ver. 5.0. 
The software architecture supports the PCI and GPIO bus. The software is tested and 
proven on the PCI platform using the PLX9054 bridge. 
Remark: It is assumed that the reader is well versed with the Windows CE development 
environment and fully understands the driver development for Windows CE Ver. 5.0. 
2.  Installing the ISP176x host software 
1.  Install the ISP176x host software on the PC using the setup utility. 
2.  Under the WINCE500 root directory, create directory 3rdParty. Under 3rdParty create 
directory ST-ERICSSON. 
3.  Copy directories PhISP1761HCD and PhISP1761Bus from the eval kit disk to 
directory \WINCE500\3rdParty\ ST-ERICSSON\. 
4.  Copy CEC files ISP1761Host.cec and PCIKit.cec from the eval kit disk to folder 
\WINCE500\PUBLIC\COMMON\OAK\CATALOG\CEC. 
3.  ISP176x HCD Windows CE Ver. 5.0 operating system design 
This section explains the steps involved in adding Windows CE Ver. 5.0 ISP176x HCD 
and its dependent modules for x86 processor. 
1.  Install Windows CE Ver. 5.0 with your selected BSP. 
After installing Windows CE Ver. 5.0, follow the steps to add the ISP176x HCD and its 
dependent modules. 
2.  Create a platform workspace with your BSP. 
 