Epson G3 Series Manuale Utente

Pagina di 92
Setup & Operation    5. Motion Range 
  
5.3    Setting the Cartesian (Rectangular) Range   
 
in the XY Coordinate System of the Manipulator (for Joints #1 and #2) 
Use this method to set the upper and lower limits of the X and Y coordinates. 
This setting is only enforced by software.  Therefore, it does not change the physical 
range.    The maximum physical range is based on the position of the mechanical stops. 
 
 
EPSON 
RC+ 
 
Set the XYLim setting on the [XYZ Limits] panel shown by selecting [Tools]-[Robot 
Manager]. 
(You may also execute the XYLim command from the [Command Window].) 
 
 
5.4  Standard Motion Range 
The following “motion range” diagrams show the standard (maximum) specification.  
When each Joint motor is under servo control, the center of Joint #3’s (shaft’s) lowest 
point moves in the areas shown in the figure. 
“Area limited by mechanical stop” is the area where the center of Joint #3’s lowest point 
can be moved when each joint motor is not under servo control. 
“Mechanical stop” sets the limited motion range so that the center of Joint #3 cannot move 
beyond the area mechanically. 
“Maximum space” is the area that contains the farthest reach of the arms.  If the 
maximum radius of the end effector is over 60 mm, add the “Area limited by mechanical 
stop” and “radius of the end effector”.    The total value is specified as the maximum area. 
G3 Rev.1 
57