Epson V7 Manuale Utente

Pagina di 344
4-46 
1. Ethernet
• System memory: $s518
No.
Contents
Solution
0
Normal
200
Failed in send request
Check cable connection and network table setting of 
the target station.
201
Send error
Check that the setting on the target station is 
consistent with the network table setting.
202
Internal port error
The communication unit is in the older version or is 
faulty.
204
TCP connection over
The number of connections reaches the maximum, 
and no more connection is possible.  Check the 
communication lines.
205
TCP connection error
Connection cannot be established.  Check the 
communication lines, or turn the power off and on.
206
TCP connection end error
TCP communication disconnection has failed.  Check 
that the communication partner with the V7 series is 
present on the line.
207
TCP send error
TCP sending has failed.  Check the communication 
lines.
350
Send buffer full
The line is busy.  Consult the network administrator of 
your company.  The communication unit is in the older 
version or is faulty.
351
IC receive buffer overflow
352
Driver receive buffer overflow
801
Receive processing error, link down error
Check the HUB or the link confirmation LED on the 
communication unit.  If the LED is not on, check cable 
connection and the port setting on the network table.
802
Transceiver error
Check the transceiver and cable connection.
900
No IP address at local port
Check that the IP address of the local port is set on 
the network table.  Check if the same IP address is set 
on the network.
901
Duplicated IP address error
902
Send socket ID error (error that may 
occur when V7i LAN port is used)
Turn the power off and back it on.  If the problem 
persists, contact your local distributor.
1000
Ethernet I/F unit not mounted
Check whether the Ethernet I/F unit is mounted 
correctly, and then turn the power off and on.  If the 
problem persists, contact your local distributor.
1001
Ethernet I/F unit not ready
1002
Ethernet I/F unit DPRAM error
1003
No response from Ethernet I/F unit
1004
Ethernet receive buffer over
1005
Ethernet send registration error
1006
I/F unit unregistered interrupt
1100 - 1115
Initialization error (communication unit)
1120
Dual port access error
1200
Undefined register
1201
Send/receive buffer area over
1202
MAC address error
1203
Port error
Check whether the Ethernet I/F unit is mounted 
correctly, and then turn the power off and on.  If the 
problem persists, contact your local distributor.
1301
Watch dog overflow
1302
JAVA error LANC error