Epson V7 Manuale Utente

Pagina di 344
5
1. MITSUBISHI PLC
5-21
Co
nne
3. PLC programming software communication setting
For communication specifications between the PLC programming software and the 
PLC, the communication parameter settings for the V7 series and the PLC can be used.  
Select [Comm. Parameter] from the [System Setting] menu and check the settings in 
the [Comm. Parameter] dialog.
• Baud rate setting
There will be no problem if the setting for [Baud Rate] in the [Comm. Parameter] 
dialog of the V-SFT editor is not consistent with the baud rate setting on the PLC 
programming software.  The baud rate set on the PLC programming software is 
automatically selected when communications (monitoring, etc.) are performed.  
When the V7 series is turned off and back on, the setting for [Baud Rate] in the 
[Comm. Parameter] dialog becomes valid again.
4. Transferring the ladder communication program
When transferring screen data, the ladder communication program is also transferred.  
To transfer the ladder communication program only, follow the procedure described 
below.
1) Select [Ladder com. prg.] in the [Transfer] dialog, and click [PC->].
2) The dialog shown on the right is 
displayed.  Select “MelQHCpQ.lcm” and 
click [Open].  The program is 
transferred to the V7 series.
Notes on Ladder Transfer Function
1. When [Ladder Tool] is selected for a modular jack, monitor registration on the PLC is 
prohibited so that the screen display speed becomes slower than usual during 
communications between the V7 series and the PLC even if the PLC programming 
software is not started.
2. Also, when the ladder program is transferred in the RUN mode of the V7 series, 
communications are synchronized; therefore, the performance of both the V7 series 
and the PLC programming software decreases.