Connecting to the Network
Enterasys NAC Controller Hardware Installation Guide 4-13
Figure 4-11  Cable Connection to LC Fiber-Optic Connectors
3.
Verify that a link exists by checking that the port RX LED is on (flashing amber, blinking 
green, or solid green). If the RX LED is off, perform the following steps until it is on:
a.
Verify that the device at the other end of the segment is ON and connected to the segment.
b. If there are separate fiber‐optic connections on the other device, check the crossover of the 
cables. Swap the cable connections if necessary.
c.
Check that the fiber‐optic connection meets the dB loss and cable specifications outlined 
in the Cabling Guide for multimode fiber‐optic cabling. To obtain this document, refer to 
If a link has not been established, refer to 
 for LED troubleshooting details. If a 
problem persists, refer to “
 for details on contacting 
Enterasys Networks for support.
4.
Repeat steps 1 through 3, above, until all connections have been made.
Installed Mini-GBIC LC connector
Receive LED (RX)
LC cable connector
Transmit LED (TX)
Release tab