Elmo Server 1.3 Manuale Utente

Pagina di 74
Chapter 3: Installation 
3.1 
Before You Begin 
3.1.1 Site 
Requirements 
You can guarantee the safe operation of the Tuba by ensuring that it is installed in an 
appropriate environment. 
Feature Value 
Ambient operating temperature 
0 °C – 40 °C (32 °F – 104 °F) 
Maximum relative humidity 
90% non-condensing 
Operating area atmosphere 
No flammable gases or vapors permitted in area 
Models for extended environmental conditions are available. 
 
 
The Tuba dissipates its heat by forced ventilation (fan). The maximum 
operating ambient temperature of 0 °C – 40 °C (32 °F – 104 °F) must not be 
exceeded. 
3.1.2 Hardware 
Requirements 
3.1.2.1 
AC Input Requirements 
Circuit Breakers & Contacts 
Three-phase Supply Voltage  Single-phase Supply Voltage 
Circuit breaker current rating  150% - 200% of drive current 
200% ~ 300% of drive current 
Circuit breaker voltage rating 
250VAC / 480 VAC depending upon operating AC voltage 
Contactor 
Up to 150% of drive current 
Up to 200% of drive current 
 
3.1.2.2 
Recommended Wire Cross-sections (All Models) 
Feature Connection 
Details 
AC input 
AC1, AC2, AC3 
4 ~ 5 mm
2
, 10 ~ 12 AWG 
Motor 
M1,  M2,  M3 
4 ~ 5 mm
2
, 10 ~ 12 AWG   
Protective earth 
PE, PE 
4 ~ 5 mm
2
, 10 ~ 12 AWG   
Auxiliary power 
24v     +, – 
0.5 ~ 1 mm
2
,  18 ~ 20 AWG  
Tuba Installation Guide 
 
MAN-TUBIG (Ver. 1.3)
 
 
3-1