Furuno SC-60 Manuale Utente

Pagina di 106
2. INSTALLATION 
 
 
 2-21
2.6.3 
Heading data format 
1.  Turn off the processor unit. 
2.  Unfasten four screws from the processor unit to remove the top cover.   
3.  Choose the heading format of the equipment connected to the ports HDG 
OUT 1, HDG OUT 2 and HDG OUT 3 with the jumper wires on the circuit 
board 20P8171, referring to the table below. The default setting for each port 
is AD-10. 
Jumper wire and format on the circuit board 20P8171 
Port Format
Setting 
Remarks 
AD-10 
J11 < - > J13 
HDG OUT 1 
NMEA 
J11 < - > J12 
AD-10 
J14 < - > J16 
HDG OUT 2 
NMEA 
J14 < - > J15 
AD-10 
J17 < - > J19 
HDG OUT 3 
NMEA 
J 17 < - > J18 
NMEA and AD-10 are identified 
on the circuit board. Choose 
NMEA for IEC 61162-1 
sentences. 
BEA
CON
HEAD1
ANGULAR
RATE SENSOR
HEAD2
HEAD3
NMEA
(IEC 61162)
NMEA (IEC 61162)
NMEA (IEC 61162)
AD-10
AD-10
AD-10
20P8171
 
Processor unit, cover opened, top view