Cooper Lighting 6105 Dépliant

Pagina di 2
T I M E
L I G H T
+
Test
20
15
1
5
10
AUTO
OFF
ON
6105
Motion Sensing
Wall Switch
The  6105  Motion  Sensing  Wall  Switch  detects  motion  to  turn  on
lights for an adjustable amount of time.  A built-in photo cell can be set 
to keep lights off when the lights aren't needed.  The unit has excel-
lent sensitivity and a wide 150° detection range.  It can be used with 
incandescent  lighting  as  well  as  rapid  start  fluorescent  lighting.  (Not 
for use with electronic ballasts)
Installation  is  as  easy  as  replacing  a  wall  switch.    However,  some 
codes require installation by a qualified electrician.
Features include:
• 150° motion detection angle.
• Adjustable on-time from 5 sec. to 20 min.
• Adjustable photocell.
• Works with incandescent and rapid start fluorescent lighting.  
  (Not for use with electronic ballasts)
• Works with motors up to 1/8 hp.
• Slide switch selectable OFF, ON AND AUTO modes.
WARNING: Turn power off at the circuit breaker before wiring.
TYPICAL INSTALLATION
Control Cover
Plate Removed
MODE
Selection
Switch
• Remove the decorative coverplate (secured by two
   screws).
• Remove Control Cover.  (Press in with screwdriver.    
  Swing out cover to  remove.)
• Remove the existing switch (if this is a retrofit
   application).
• Connect the detector as shown in the diagram.   
   Before installing the detector into the box, make 
   sure there is no wire exposed at the connection.
• Do not connect to neutral wire or damage to unit  
  will occur.
If you have a problem with your Wall Switch, first follow this guide.  If the problem persists, call the   
customer service hotline at 1-866-853-4293 between 8:00 AM and 7:00 PM ET weekdays.
Electrical  input................................................................................................................................120V,  60  Hz
Fluorescent Load (Not for electronic ballasts)....................(2) 30 Watt minimum 400 Watt maximum Rapid Start
Motor  Load.............................................................................................................................1/8  HP  maximum
Incandescent.........................................................................................................................500W  at  120V  AC
On-Time..........................................................................................Adjustable  approximately  5  sec.  to  20  min.
Photocell  Sensor.......................................................................................From  dull  daylight  to  less  than  1  FC.
Coverage...............................................................................up to 15 ft. at 150°, up to 30 ft. in front of the sensor
There are 6 preset selections for the amount 
of time the lights stay on: Test (5 seconds), 
1, 5, 10, 15, and 20 minutes. Use a small, 
phillips screw driver to adjust the TIME 
control. Turn the TIME control until it “snaps” 
into the desired time position.
Replace control panel cover and install the decorative wall plate.  In installations where the Cooper motion 
sensor switch is combined with other switches or outlets on an expanded box, a combination wall plate will 
need to be purchased.  Various combination wall plates are available at Home Centers and Electrical Supply 
Stores.
Slide the switch a couple of times to  make sure it operates freely.
When the light in the room is at the 
level you want the lights to turn on, 
set the switch to the AUTO position.
Put  the TIME  control  to  the  5  sec-
ond position.
Put  the  LIGHT  control  to  the  mini-
mum  dark  (fully  counter-clockwise) 
position.   Wait  for  the  lights  to  turn 
off.
Turn  the  LIGHT  adjustment  clock-
wise in very small steps and wait 2 
seconds before moving your hand in 
front of the sensor.  Repeat until the 
lights controlled by the sensor come 
on.  The light will now come on when 
the light level is at or below the pres-
ent level and motion is detected.
To adjust the photocell:
MODE Selection Switch
Moving the switch selects one of three modes of operation: OFF, AUTO, ON
OFF: Lights stay off.
AUTO:  Lights come on for time set when motion is detected and the light level is below the set level.
ON:  Lights stay on continuously.
 
 
 
The  sensor  can  be  prevented  from  turning  on  lights 
when  there  is  already  enough  light  in  the  room.    Use 
a  small  screw  driver  to  set  the  light  level  using  this  
diagram  as  a  guide.    In  the  fully  clockwise  position, 
the  sensor  turns  on  lights  even  in  full  daylight.    In  the 
fully  counter-clockwise  poition,  the  sensor  only  turns 
on  lights  when  the  surrounding  light  level  is  very  low.
ADJUSTMENTS
SPECIFICATIONS
TROUBLESHOOTING
USE
TIME
Complete Installation
LIGHT LEVEL
OFF
ON
AUT
O
- 2 -
- 3 -
- 4 -
• Mount the detector into the wall box with the mounting screws.
• For test purposes, use a small screwdriver to turn the time control to TEST and the light control fully clockwise.  
Turn the power back on at the circuit breaker.
• Set the switch to the AUTO mode.  When unit stabilizes (about 1 minute) the sensor is ready to detect motion. If 
motion is detected, the lights will turn on.  The lights will turn off 5 seconds after motion is no longer detected.
(NEUTRAL)
Green ground wire to
junction box screw or
grounding wire.
BLACK
LOAD
HOT
(LINE)
T I M E
L I G H T
+
Test
20
15
1
5
10
5 Seconds
20 Minutes
Any Light
Level
Dark (low
light level)
SYMPTOM
Light does not come
on.
Lights do not stay
on in the Auto mode.
POSSIBLE CAUSE
Circuit  breaker  or  fuse  is 
turned off.
If  the  lamp  being  con-
trolled has another switch, 
it may be turned off.
Bulb is defective.
LIGHT  control  is  set  too 
far toward the DARK posi-
tion.    MODE  switch  is  set 
to OFF instead of AUTO.
Poor connection.
Motion has stopped in the 
room.
TIME control is set for too 
short a delay.
1.
2.
3.
4.
5.
6.
1.
2.
SYMPTOM
Light does not 
turn off.
Light comes on for 
no reason in the Auto 
mode.
POSSIBLE CAUSE
Incorrect wiring.
MODE switch is set to 
ON instead of AUTO.
Motion is still present.
Delay  set  by  TIME 
c o n t r o l   h a s   n o t 
expired.
Heating or cooling ob- 
jects  (such  as  air 
vents,  appliances,  or 
drafts through the wall 
box) are causing false 
triggering.
Switch  on  the  sensor 
has  been  turned  off 
and back on.
There  was  a  momen-
tary  power  interrup-
tion.  The light will turn 
off automatically when 
the "on" time expires.
1.
2.
3.
4.
1.
2.
3.
YOUR COOPER WIRING DEVICES MOTION SENSOR TWO YEAR LIMITED WARRANTY
For a period of 2 years from the date of purchase, Cooper Wiring Devices will replace or repair the motion 
sensing switch provided that it has not been subject to abuse, improper installation or improper use, and 
is  returned  prepaid  Cooper Wiring  Devices  Quality  Control  Department  at  203  Cooper  Circle,  Peachtree 
City, GA 30269.  If the product has been discontinued, replacement will be made with the nearest available 
equivalent  model.   This  warranty  does  not  cover  consumables  (such  as  fuses).    Proof  of  purchase  in  the 
form of a bill of sale or receipted invoice that shows that the item is within the applicable warranty period 
must be presented to obtain the repair or replacement provided by the warranty.  Repair or replacement as 
provided under this warranty is the exclusive remedy of the customer.  Cooper Wiring Devices shall not be 
liable  for  any  incidental  or  consequential  damages  for  breach  of  any  express  or  implied  warranty  on  any 
of its products.  Except to the extent limited or prohibited by applicable law, any implied warranty of mer-
chantability or fitness for a particular purpose on this product is limited in duration to the duration of this 
warranty.  Some states do not allow the exclusion or limitation of incidental or consequential damages, or 
allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.  This 
warranty gives you specific legal rights and you may also have other rights which vary from state to state.
LIGHTING  
LOAD
GENERAL APPLICATION INFORMATION
The detector is more sensitive to motion across the front of the sensor than to motion towards the sensor.
The detector senses heat in motion and possible heat sources that change temperature quickly.  Therefore, to  
avoid false triggering, avoid placing the sensor where it will be aimed at air conditioners, heaters, and other 
sources of heat or cold.
NEW APPLICATION
Choose  a  location  where  the  motion  sensor  has  a  clear  view  of 
the entire area where occupant motion may occur.
RETROFIT APPLICATION
Motion sensing switch will replace existing wall switch.  Use only 
where  the  existing  switch  location  provides  a  clear  view  of  the 
occupied area.
Included are: • The sensor switch • Cover plate • 3 wire connectors • 2 large screws • 2 small screws.
INSTALLATION
INSTALLING THE SWITCH
SELECT A LOCATION
Typical Plan View of Coverage
30'
15'
0'
WARNING: For indoor use only.
Questions?  Call  1-866-853-4293  8:00 AM to 7:00 PM Eastern Time, weekdays
469MV-PT
Note: Adjusting screws 
found under (Off-Auto-On) 
face plate.
BLACK
598-1177-03 E