Cooper Lighting 84700 Manuale Utente

Pagina di 41
9131 
Rev. M 
 
6.9   
Option -9 
 
Item 11 P/N is 10047-1878.  Item 12 P/N is 46-192-5X/D-8.  The part number for the 
interlock switch harness is 31985-1.  Item 5 P/N is the same as for standard 84700-2 
module, except option  -9 labeling required and, if present, remove lead with tag 
"THIS JUMPER TO BE REMOVED ONLY WHEN CONNECTING LOAD TO 
THESE TERMINALS".  See Figure 6-9A for parts location.  See Figure  6-9B for 
wiring diagram. 
 
6.10  
Option -10 
 
Cabinet P/N is 30834 for 84700-1 or -2 and 30835 for 84700-3 or -4. 
 
6.11   
Option -11 
 
Item 4 circuit card, see Figure 5-1 or 5-2 for location, changes with Option -11.  See 
Table 6-1 for circuit card part number variations.  See Figure 6-3,-4,-11 for external 
remote control connections. 
 
6.12   
Option -12 
 
Item 14 P/N is 10047-2276 (except when used with Option  -9; use Option  -9 Item 
14).  The actuator extender P/N is 10037-573.  Item 10 P/N for 84700-1 or  -2 is 
31986 and 31987 for 84700-3 or -4.  See Figure 5-1 or 5-2 for parts location. 
 
6.13   
Option -13 
 
Cabinet P/N is 30834-1 for 84700-1 or -2 and 30835-1 for 84700-3 or -4. 
 
6.14 
OPTION -14 
 
Circuit Selector Switch without the Cabinet. 
 
6.15 
OPTION -15 
 
The  part number for the 480VAC transformer is 10047-1444.  Customer primary 
input connections are at points H1 and H4 on the transformer;  see Figures 6-2A and 
6-2B.  See Figure 5-1 or 5-2 for transformer location. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
26