Friedrich C-90B Manuale Utente

Pagina di 12
7
TROUBLESHOOTING ELECTRONIC AIR CLEANER
Electrical  Troubleshooting  Procedure  for  Electronic  Air  Cleaner
Make sure elec-
tronic cell is clean, 
dry and properly 
installed
Make sure pre-fi lter and acti-
vated carbon fi lter are properly 
installed, and carbon fi lter is 
activating fi lter interlocking 
switch lever.
Replace the access 
cover and turn the air 
cleaner on.  Check Low, 
then Med, then Hi on 
multispeed fan.
Check fan and 
neon light.
Both
Off
Push interlock 
switch with plastic 
handled screw-
driver.  Short from 
cell frame to a hot 
collector plate.
Arcing
Yes
Electronic 
Air Cleaner is 
OK.
Both
Off
120 VAC Present
Jumper fan 
switch contacts
- For each speed 
in turn on multi-
speed fans.
Inspect cell for
-  Bent Collector Plates
-  Broken Ionizer Wires
-  Dirt on Insulators
-  Damaged or dirty  
    Contact Tabs
Replace Cell
Infi nite
Resistance
Cell OK
Check Contact Board for 
coating on ground contacts
Clean
Dirty
Clean contacts with fi ne 
grain sandpaper or emery 
cloth.
Check wire connections 
are secured properly
OK
Replace Power Board 
Assembly
Replace Switch
Turn OFF power.  Make 
sure shaft on fan motor 
rotates freely. Check for 
open windings. Replace if 
necessary.
Repair or 
replace cell
No cell damage noted
Lamp
Off
Fan
On
Replace Sys-
tem Switch or 
fan motor.
Check fi lter Inter-
locking Switch, 
Access Cover 
Interlocking 
Switch, System 
Switch.
With Ohmmeter, check 
for short between
-  Cell Frame and Ionizer 
Section
-  Cell frame and Collec-
tor Section
Light 
Off
Voltage above 120 VDC
Voltage 
correct
Replace Light
Voltage NOT 
Correct
Check wiring back 
through switch, power 
cord, and outlet to cir-
cuit breaker or fuse.
Remove cell.  
Replace access 
cover, Check 
neon light.
Check 100 VDC 
voltage across 
terminal on lamp.
Light OK, replace 
complete power 
supply
Check Line 120 
VAC power.  Cor-
rect as needed.
Fan
On
Light 
On
Cell 
Shorted
START
Voltage 
Below 
70 VDC
Light 
Off
Arcing
No
Fan
Off
Cell
Damaged
Remove access 
cover.  Check 
for correct input 
voltage: 120 VAC.  
Models P1 and P2 
terminals on 
power supply.
Lamp
On
Fan
Off
Fan
On
TO USE THIS CHART:
1. 
Follow the steps in order.  Don't skip around.
2. 
Each time you isolate and fi x a problem, go back to 
START.
3. 
Repeat ALL the steps until the air cleaner checks out OK
WARNING
Some of these steps expose dangerous high 
voltage.  Only a qualifi ed service technician 
should attempt this procedure.
WARNING
Electronic components on power supply 
board are not fi eld replaceable.  Attempt-
ed service will damage the board.