Flowmatic Water System FMR04-ZW Manuale Utente

Pagina di 16
Start up Instructions
Warning: To prevent the possibility of electrical shock, clean up any water on
cabinet floor and dry all water from outside of RO unit.
Turn on the incoming hot and cold water angle stop valves. Turn
on the water line needle valves by turning counter clockwise.
Check the system for leaks and tighten fittings as necessary.
Note: Check daily over the next week to ensure no leaks are
present.
Step 2
Plug the (24 volt) transformer power cord
connector into the RO system wire harness connector (labeled
transformer.)
Step 3
Plug the transformer into the electrical outlet under the sink.
Step 4
Ensure ball valve on tank is open.
Step 5
Open the RO faucet and leave it open until water begins to drip. Then close the faucet. The
tank will take 2 to 4 hours to fill completely.
Note: Water may be cloudy or milky due to air in the system. This conditions will
resolve its self after a couple of tanks of water. After a final filter change you will see
gray water until the carbon particles have flushed from the filter.
Step 6
After the tank has filled once, open the RO faucet and drain the tank.
Step 7
Close RO faucet and allow the tank to fill, (2-4 hours). System is now ready to use.
Note: This system can be hooked up to an ice maker. Place a tee after the final filter and before the
faucet. It is recommended to install a ball valve on the ice maker line. This enables you to shut off the
water supply to ice maker while the tank is filled and flushed to remove the carbon particles from the final
filter. Each time the tank becomes empty you will need to close the water supply to the ice maker until
the tank refills.
Semi-annual maintenance
Step 1
Turn off the water supply line needle valves.
Step 2
Close the ball valve on the tank.
Step 3
Open the RO faucet to allow the system to depressurize for 5 - 10 minutes before
attempting to remove Housings.
Step 4
Unplug transformer from electrical outlet.
Step 5
Carefully remove the filter housings and pour water out of the housings. Dispose of
the used filters.
Step 6
Wash housings with mild soap and rinse thoroughly with water.
Step 1
8