Chauvet LEDRAIN 64C Manuale Utente

Pagina di 17
 
4. Operating Instructions 
4/19/2010 12:44 PM 
 
4.
 
O
PERATING 
I
NSTRUCTIONS
 
 
Configuring the Starting Address 
 
Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for 
control begins to read the data on the channel indicated by the starting address. For example, a 
fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data 
from channels: 100, 101, 102, 103, 104, 105 and 106. Choose the starting addresses for each fixture 
so that the channels used do not overlap. In addition, you should note the starting address selected 
for future reference. 
The 
LEDrain™ 64C fixture uses seven or three DMX channels. If this is your first time using DMX, we 
recommend 
reading the “DMX Primer” section in the “Appendix”. 
 
DMX Operation 
 
 
This is the operating mode which will allow for control with an external DMX controller. You must set 
the starting address for this mode. If this is your first time using DMX, then it is recommended that 
you refer to the “DMX Primer” section in the “Appendix” of this manual. 
 
 
Mode 
 
DIP switches 
DMX  
 
1~9 = set to the DMX starting address 
 
 
 
10 = Off 
 
Accessing the 2 Personalities 
There are two personalities for this fixture. There is the standard 7-channel personality with strobe 
and color macros, and then there is the basic 3-channel RGB personality. Please see the DIP switch 
settings to access each of these personalities below. 
 
Mode 
 
DIP switches 
7-CH 
 
11-12 = Off 
3-CH 
 
11 = On