Chauvet Projector 3 Manuale Utente
5. Appendix
9
5.
A
PPENDIX
General Troubleshooting
S
YMPTOM
P
OSSIBLE
C
AUSE
(
S
)
P
OSSIBLE
A
CTION
(
S
)
Breaker/Fuse
keeps blowing
·
Excessive circuit load
·
Check total load placed on the
electrical circuit.
·
Short circuit along the power
wires
·
Check for a short in the electrical
wiring (internal and/or external).
Device does not
power up
·
No power
·
Check for power on Mains.
·
Loose power cord
·
Check power cord
Fixture is not
responding to DMX
·
Wrong DMX addressing
·
Check Control Panel and unit
addressing
·
Damaged DMX cables
·
Check DMX cables
·
Wrong polarity settings on the
controller
·
Check polarity switch settings on
the controller
·
Loose DMX cables
·
Check cable connections
·
Faulty DMX interface
·
Replace DMX input
·
Faulty Main PCB
·
Replace Main PCB
Loss of signal
·
Non DMX cables
·
Use only DMX compatible cables
·
Bouncing signals
·
Install terminator as suggested.
·
Long cable / Low level signal
·
Install amplifier right after fixture
with strong signal.
·
Too many fixtures
·
Install an optically coupled DMX
splitter after unit #32.
·
Interference from AC wires
·
Keep DMX cables separated from
power cables or black lights.
If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.
Technical Support.