Troubleshooting (continued)
Problem
Burner(s) will not  light 
using ignitor.
(See Electronic Ignition 
Troubleshooting also)
Burner(s) will not
match light.
Sudden drop in gas
flow or low flame.
Flames blow out.
Flare-up.
Persistent grease fire.
Flashback...
(fire in burner tube(s)).
Unable to fill LP 
cylinder.
One burner does not 
light from other 
burner(s).
Possible Cause
ELECTRONIC IGNITION:
• No spark, no ignition noise.
• No spark, some ignition noise.
• Sparks, but not at electrode or at full 
strength.
• See “GAS ISSUES:” on previous page.
• Match will not reach.
• Improper method of match-lighting.
• Out of gas.
• Excess flow valve tripped.
• Vapor lock at coupling nut/LP cylinder 
connection.
• High or gusting winds.
• Low on LP gas.
• Excess flow valve tripped.
• Grease buildup.
• Excessive fat in meat.
• Excessive cooking temperature.
• Grease trapped by food buildup around 
burner system.
• Burner and/or burner tubes are blocked.
• Some dealers have older fill nozzles 
with worn threads.
• Grease buildup or food particles in 
end(s) of carryover tube(s).
Prevention/Solution
• See Section I of Electronic Ignition System.
• See Section II of Electronic Ignition System.
• See Section III of Electronic Ignition System.
• Use long-stem match (fireplace match).
• See “Match-Lighting” section of Use and Care.
• Check for gas in LP cylinder.
• Turn off knobs, wait 30 seconds and light grill. If flames are still low, 
turn off knobs and LP cylinder valve. Disconnect regulator. 
Reconnect regulator and leak-test. Turn on LP cylinder valve, wait 
30 seconds and then light grill.
• Turn off knobs and LP cylinder valve. Disconnect coupling nut from 
cylinder. Reconnect and retry.
• Turn front of grill to face wind or increase flame height.
• Refill LP cylinder.
• Refer to “Sudden drop in gas flow” above.
• Clean burners and inside of grill/firebox.
• Trim fat from meat before grilling.
• Adjust (lower) temperature accordingly.
• Turn knobs to OFF. Turn gas off at LP cylinder. Leave lid in position 
and let fire burn out. After grill cools, remove and clean all parts.
• Turn knobs to OFF. Clean burner and/or burner tubes. See burner 
cleaning section of Use and Care.
• The worn nozzles don’t have enough “bite” to engage the valve. Try 
a second LP dealer.
• Clean carry-over tube(s) with wire brush.
AUTO-CLEAN™
Possible Cause
Prevention/Solution
(If Equipped)
Ÿ
Replace batteries
Ÿ
Install batteries correctly.
Ÿ
Push Knob in to start the clean cycle. (Green LED should begin to 
flash)
Timer does not work 
(Green light does not 
flash)
Ÿ
Dead Battery
Ÿ
Batteries installed incorrectly.
Ÿ
Knob Position did not start the Clean 
Cycle
Ÿ
Replace batteries
No LED’s will illuminate
Ÿ
Dead Battery
Ÿ
Prepare to replace batteries (NOTE: Clean cycle will operate with 
a weak battery.
Red LED next to battery 
symbol is illuminated
Ÿ
Low Battery Strength
24