Carrier D2-3466-2 Manuale Utente

Pagina di 38
Troubleshooting the Drive
6-5
Table 6.1 – Resistance Checks
Input 
Diode 
No.
Meter 
Connection 
(+)       (-)
Component is OK if
resistance (R) is:
Component is defective if:
1
   *      SCR1
    10 < R < 1 megohm
Continuity (short circuit) or 
open when the meter is 
connected with reversed 
polarity.
2
   *      SCR2
3
   *      SCR3
4
   *      SCR4
5
   *      SCR5
6
   *      SCR6
7
SCR1    **
  
 
8
SCR2       
**
9
SCR3       
**
10
SCR4    **
11
SCR5    **
12
SCR6    **
* (+) DC Bus Volts power terminal
** (-) DC Bus Volts power terminal
                                                Table 6.1 - Resistance Checks (Continued)
IGBT 
No.
Meter 
Connection
(+)        (-)
Component is OK if 
resistance (R) is:
Component is defective if:
1
*        W/T3
     10 < R < 1 megohm
Continuity (short circuit) or 
open when the meter is 
connected with reversed 
polarity.
2
*        V/T2
3
*        U/T1
4
W/T3    ** 
5
V/T2     **
6
U/T1    **
* (+) DC Bus Volts power terminal
** (-) DC Bus Volts power terminal