8
Installation /
Assemb
ly
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
2) Having at least two ventilation openings at cylinder valve level in
the side wall, equally sized, spaced at 180 degrees (3.14 rad), and
unobstructed. Make sure each opening has a total free area of not
less then ½ square inch per pound (3.2 sq. cm/kg) of stored fuel
capacity and not less then a total free area of 10 square inches
(64.5 sq. cm).
Ventilation openings need to be provided at floor level with a total
free area of ½ inch per pound (3.2 sq. cm/k) of stored fuel capacity
and not less than a total free area of 10 square inches if the ventila-
tion openings at floor level are in a side wall, make sure there are
at least two openings. The bottom of the openings shall be at floor
level and the upper edge no more than 5 inches (127 mm) above
the floor. The openings need to be equally sized, spaced at 180
degrees (3014 rad) and unobstructed.
Make sure every opening has minimum dimensions to permit the
entrance of a 1/8 inch (3.2mm) diameter rod.
There shall be a minimum clearance of 2 inches (40.8mm) between
the lower surface of the floor and the LP gas supply cylinder enclosure
and the ground.
Check the rating plate to make sure the gas supply you are hooking up
Check the rating plate to make sure the gas supply you are hooking up
to is the gas type the firepit or fireplace is manufactured for.
If you do not have an updated filler valve on your existing propane
If you do not have an updated filler valve on your existing propane
tank, you will need to purchase one at your local hardware store, as
you will not be allowed to refill the tank at any filling station.
Use the pressure regulator and hose assembly supplied with LP mod-
Use the pressure regulator and hose assembly supplied with LP mod-
els. Replacement pressure regulator and hose assemblies must be
those specified in this manual.
The 20 lb LP gas cylinder used must include a collar to protect the
The 20 lb LP gas cylinder used must include a collar to protect the
cylinder valve.
Be certain to mount or set the 20 lb LP gas cylinder on a flat surface
Be certain to mount or set the 20 lb LP gas cylinder on a flat surface
and restrain it to prevent it from tipping.