Troubleshooting (cont'd)
Procedure B
1.
2.
3.
4.
Disconnect the UPAM from the paging system.
Connect a test set to PT & PR terminals on UPAM (see Figure 12).
Place the test set in the monitor position.
Make a page from a telephone system phone. Listen to the test set. Audio should be
comfortably loud (approximately telephone level) and not distorted.
If audio is loud and clear, the paging interface is working correctly. The problem
must be in the paging system.
If audio is not heard, contact Technical Support.
Figure 12. Test Procedure B
Troubleshooting Notes
Latching Relays
Under certain circumstances, the installation procedure may jar the latching relays
causing a busy tone to be heard in the handset when you try to call the UPAM.
When connected to a station port, the relays will reset when the default timer times
out (max. 35 sec.). On ground start trunk ports, short terminals T & R together for 5
seconds to reset the relays.
Ring Delay
If the pre-announce/confirmation tone can be heard over the paging system but is
shortened or absent in the handset, it may be necessary to increase the length of
ring before the UPAM answers. See Ring Delay in Section 2 for the procedure to
follow to increase the delay.
[30]